Adjustable shunts and proton therapy: a magnetic combination
Child's Nervous System · 2023
DOI: 10.1007/s00381-023-05984-3 ↗Kurz gefasst
Leserbrief in der Zeitschrift Child's Nervous System, 2023. Verfasst von Sofie Dietvorst und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, University Hospitals Leuven, Louvain, Belgium. sofie.dietvorst@uzleuven.be. Hauptthemen laut MEDLINE: Proton Therapy, Central Nervous System Neoplasms. Die Arbeit nennt 5 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Due to evidence for proton beam therapy (PBT) in pediatric central nervous system (CNS) tumors, compact proton therapy systems became commercially available to allow better integration in a hospital setting. However, these systems have a non-zero magnetic field at the level of the patient. Often, these patients have a cerebrospinal fluid shunt, and most of them are adjustable through a magnet. Whether the induced magnetic fields could interfere with adjustable shunts is unknown. METHODS: In the first five CNS tumor patients with adjustable shunts who underwent PBT, the shunt setting was controlled before, during, and after treatment with PBT. Additionally, we used an ex vivo adjustable shunt to check if the settings could be altered by the magnetic field. RESULTS: We did not observe unintentional changes in shunt settings in vivo during treatment. In ex vivo testing, the shunt settings were altered directly cranial to the exit window of PBT due to the magnetic field. CONCLUSION: Although we did not observe any shunt setting alteration during PBT in this small cohort, caution is warranted. Given the lack of high-volume data, there should be a low threshold for checking the shunt setting at the end of PBT therapy or in a symptomatic patient.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, University Hospitals Leuven, Louvain, Belgium. sofie.dietvorst@uzleuven.be.
- Department of Radiation Oncology, University Hospitals Leuven, Louvain, Belgium.
- Department of Radiology, University Hospitals Leuven, Louvain, Belgium.
- Department of Neurosurgery, University Hospitals Leuven, Louvain, Belgium.
Zitieren
APA
Dietvorst, S., Poels, K., Van Beek, K., Peeters, R., & De Vloo, P. (2023). Adjustable shunts and proton therapy: a magnetic combination. Child's Nervous System. https://doi.org/10.1007/s00381-023-05984-3
Vancouver
Dietvorst S, Poels K, Van Beek K, Peeters R, De Vloo P. Adjustable shunts and proton therapy: a magnetic combination. Child's Nervous System. 2023. doi:10.1007/s00381-023-05984-3
BibTeX
@article{Dietvorst2023,
author = {Dietvorst, Sofie and Poels, Kenneth and Van Beek, Karen and Peeters, Ronald and De Vloo, Philippe},
title = {Adjustable shunts and proton therapy: a magnetic combination},
journal = {Child's Nervous System},
year = {2023},
doi = {10.1007/s00381-023-05984-3}
}