Fachartikel in der Zeitschrift Heart and Vessels, 2024. Verfasst von Manabu Kashiwagi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan. mkashi@wakayama-med.a…. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Defibrillators, Implantable. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The relationship between subclinical atrial fibrillation (SCAF) and left pulmonary vein anatomy is unknown. This study sought to investigate whether left pulmonary vein trunk predict the development of SCAF in patients with cardiac implantable electronic device (CIED). We also examined the relationship between the duration of SCAF and left pulmonary vein trunk. We retrospectively enrolled 162 patients who underwent implantation of dual-chamber CIEDs and follow-up by remote monitoring system. Computed tomography was used to measure the length of the left pulmonary vein. During median follow up of 2.7 years, the episodes of > 6 min and > 24 h SCAF were observed in 61 (37.7%) and 24 (14.8%) patients, respectively. The diagnosis of sinus node disease (HR: 3.66 [2.06-6.52], P 6 min and > 24 h SCAF, respectively. Length of the left pulmonary vein trunk was an independent predictor for > 6 min SCAF (HR: 1.06 [1.02-1.10], P 24 h SCAF (P = 0.06). Sinus node disease, size of the left atrium and length of the left pulmonary vein trunk were related to SCAF. The left pulmonary vein trunk might especially contribute as a trigger rather than as a driver of development of atrial fibrillation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationPulmonary VeinsDefibrillators, ImplantableHumansMaleFemaleRetrospective StudiesAgedMiddle AgedPacemaker, ArtificialRisk FactorsFollow-Up StudiesTime Factors

Stichwörter der Autor:innen

Cardiac implantable electronic deviceLeft pulmonary vein trunkSubclinical atrial fibrillation

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan. mkashi@wakayama-med.ac.jp.
  • Department of Cardiovascular Medicine, Wakayama Medical University, 811-1, Kimiidera, Wakayama City, Wakayama, 641-8509, Japan.

Zitieren

APA

Kashiwagi, M., Kuroi, A., Higashimoto, N., Mori, K., Terada, K., Katayama, Y., Takemoto, K., Taruya, A., Shiono, Y., Tanimoto, T., Kitabata, H., & Tanaka, A. (2024). Association of left pulmonary vein trunk and subclinical atrial fibrillation in patients with cardiac implantable electronic device. Heart and Vessels. https://doi.org/10.1007/s00380-024-02423-4

Vancouver

Kashiwagi M, Kuroi A, Higashimoto N, Mori K, Terada K, Katayama Y, et al. Association of left pulmonary vein trunk and subclinical atrial fibrillation in patients with cardiac implantable electronic device. Heart and Vessels. 2024. doi:10.1007/s00380-024-02423-4

BibTeX
@article{Kashiwagi2024,
  author = {Kashiwagi, Manabu and Kuroi, Akio and Higashimoto, Natsuki and Mori, Kazuya and Terada, Kosei and Katayama, Yosuke and Takemoto, Kazushi and Taruya, Akira and Shiono, Yasutsugu and Tanimoto, Takashi and Kitabata, Hironori and Tanaka, Atsushi},
  title = {Association of left pulmonary vein trunk and subclinical atrial fibrillation in patients with cardiac implantable electronic device},
  journal = {Heart and Vessels},
  year = {2024},
  doi = {10.1007/s00380-024-02423-4}
}
Kostenlos starten →