Measurement of three-dimensional flow field and wall shear stress for wall-deformable cerebral aneurysm under pulsatile flow

K. Katayama, T. Kawakami, Y. Ichikawa, K. Kamiya, R. Fujita, H. Takao, Y. Murayama, K. Yamamoto, M. Motosuke

Experiments in Fluids · 2026-06 · 67 (6)

DOI: 10.1007/s00348-025-04161-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experiments in Fluids, online erschienen am 23.05.2026. Verfasst von K. Katayama und 8 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tokyo University of Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cerebral aneurysms, which can lead to subarachnoid hemorrhages upon rupture, present challenges in predicting such ruptures due to unclear mechanisms. Prior research highlights the importance of wall shear stress (WSS) in aneurysm rupture. Contradictory findings on the role of high WSS, low WSS, WSS gradient, and oscillatory shear index necessitate further investigation, particularly under pulsatile flow conditions. This study aims to develop a robust method for accurate WSS calculation that accounts for the complex flow structures within aneurysms. Using scanning-stereoscopic particle image velocimetry (SSPIV), we estimated three-dimensional wall positions from particle image captured in a Y-shaped aneurysm model. Moreover, an elastic, patient-specific model under pulsatile flow conditions revealed periodic changes in shape and WSS distribution synchronized with the flow rate. Our method achieved a wall reconstruction accuracy within 0.6%. The results demonstrate the potential of WSS measurement with elastic walls under pulsatile flow to provide insights into aneurysm growth and rupture mechanisms.

Förderung

  • Tokyo University of Science

Zitieren

APA

Katayama, K., Kawakami, T., Ichikawa, Y., Kamiya, K., Fujita, R., Takao, H., Murayama, Y., Yamamoto, K., & Motosuke, M. (2026). Measurement of three-dimensional flow field and wall shear stress for wall-deformable cerebral aneurysm under pulsatile flow. Experiments in Fluids, 67(6). https://doi.org/10.1007/s00348-025-04161-3

Vancouver

Katayama K, Kawakami T, Ichikawa Y, Kamiya K, Fujita R, Takao H, et al. Measurement of three-dimensional flow field and wall shear stress for wall-deformable cerebral aneurysm under pulsatile flow. Experiments in Fluids. 2026;67(6). doi:10.1007/s00348-025-04161-3

BibTeX
@article{Katayama2026,
  author = {Katayama, K. and Kawakami, T. and Ichikawa, Y. and Kamiya, K. and Fujita, R. and Takao, H. and Murayama, Y. and Yamamoto, K. and Motosuke, M.},
  title = {Measurement of three-dimensional flow field and wall shear stress for wall-deformable cerebral aneurysm under pulsatile flow},
  journal = {Experiments in Fluids},
  year = {2026},
  volume = {67},
  number = {6},
  doi = {10.1007/s00348-025-04161-3}
}