EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Soft stereolithographic 3D printed phantoms for dual-modality particle image velocimetry (PIV)

Elnaz Hosseinzadeh, Hadi Mirgolbabaee, Lennart van de Velde, Michel Versluis, Erik Groot Jebbink, Alan Aguirre-Soto, Michel M. P. J. Reijnen

Experiments in Fluids · 2025-01 · 66 (1)

DOI: 10.1007/s00348-024-03938-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Experiments in Fluids, online erschienen am 08.01.2025. Verfasst von Elnaz Hosseinzadeh und 6 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The fabrication of arterial flow phantoms for fluid dynamics studies suitable for particle image velocimetry (PIV) techniques has presented challenges. Current 3D-printed blood flow phantoms with suitable transparency for optical PIV (laserPIV) are restricted to rigid materials far from those of arterial properties. Conversely, while soft 3D-printed phantoms demonstrate promise for sufficient acoustical transparency for ultrasound PIV (echoPIV), their optical translucency presents challenges for laserPIV applicability. This dual-modality approach leverages the high spatial resolution of laserPIV for in-vitro applications and the ability of echoPIV to quantify flow in both in-vivo and in-vitro application (also inside stents), providing a more comprehensive understanding of flow dynamics. In this study, we present a series of coated thin-walled 3D-printed compliant phantoms suitable for dual-modality PIV flow imaging (i.e., laserPIV and echoPIV) methods, overcoming current 3D-printable material limitations. Stereolithographic (SLA) 3D printing was used to fabricate pipe flow phantoms from a set of commercial soft resins (flexible and elastic) as vascular tissue surrogates. To overcome low transparency and poor surface finish of soft resins, we coated the 3D-printed flow phantoms with a soft, optically transparent, photo-activated polymeric coating. The feasibility of performing dual-modality PIV was tested in an in-vitro flow setup. Our results show that the average normalized root mean square errors obtained from comparing laserPIV and echoPIV velocity profiles against the analytical solutions were 3.2% and 5.1%, and 3.3% and 5.3% for the flexible and elastic phantoms, respectively. These results indicate that dual-modality PIV flow imaging is feasible in the 3D-printed coated phantoms, promoting its future use in fabricating clinically-relevant flow phantoms. Graphical abstract

Zitieren

APA

Hosseinzadeh, E., Mirgolbabaee, H., Velde, L. V. D., Versluis, M., Jebbink, E. G., Aguirre-Soto, A., & Reijnen, M. M. P. J. (2025). Soft stereolithographic 3D printed phantoms for dual-modality particle image velocimetry (PIV). Experiments in Fluids, 66(1). https://doi.org/10.1007/s00348-024-03938-2

Vancouver

Hosseinzadeh E, Mirgolbabaee H, Velde LVD, Versluis M, Jebbink EG, Aguirre-Soto A, et al. Soft stereolithographic 3D printed phantoms for dual-modality particle image velocimetry (PIV). Experiments in Fluids. 2025;66(1). doi:10.1007/s00348-024-03938-2

BibTeX
@article{Hosseinzadeh2025,
  author = {Hosseinzadeh, Elnaz and Mirgolbabaee, Hadi and Velde, Lennart van de and Versluis, Michel and Jebbink, Erik Groot and Aguirre-Soto, Alan and Reijnen, Michel M. P. J.},
  title = {Soft stereolithographic 3D printed phantoms for dual-modality particle image velocimetry (PIV)},
  journal = {Experiments in Fluids},
  year = {2025},
  volume = {66},
  number = {1},
  doi = {10.1007/s00348-024-03938-2}
}
Kostenlos starten →