EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Omission of intraoperative drain placement during robotic partial nephrectomy and robotic radical prostatectomy is safe: an analysis of 18,000 patients

John Pfail, Jake Drobner, Alain Kaldany, Kevin Chua, Benjamin Lichtbroun, Rachel Passarelli, Hiren Patel, Arnav Srivastava, David Golombos, Thomas L Jang, Vignesh T Packiam, Saum Ghodoussipour

World Journal of Urology · 2024

DOI: 10.1007/s00345-024-05320-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Urology, 2024. Verfasst von John Pfail und 11 weiteren Autor:innen. Beteiligte Einrichtung: Section of Urologic Oncology, Rutgers Cancer Institute and Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA. jp2009@rwjms.rutgers.e…. Hauptthemen laut MEDLINE: Prostatectomy, Robotic Surgical Procedures, Nephrectomy, Postoperative Complications. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Cancer Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Placement of a drain during robotic assisted partial nephrectomy (RAPN) and robotic assisted radical prostatectomy (RARP) is standard practice for many urologists and can aid in assessment and management of complications such as urine leak, lymphocele, or bleeding. However, drain placement can cause discomfort and delay patient discharge, with questionable benefit. We aim to assess the correlation between drain placement with post operative complications.

Methods

The NSQIP targeted database was queried for patients who underwent RAPN or RARP from 2019 to 2021. Our primary outcomes included 30-day complication rates stratified by intraoperative drain placement. Secondary outcomes included procedure-specific complications, length of stay (LOS), and readmissions. Multivariable regression analyses, with Bonferroni correction, were performed for each post-operative complication.

Results

We identified 4738 and 13,948 patients who underwent RAPN and RARP, respectively. Drains were not placed in 2258 (47.7%) and 6700 (48%) patients, respectively. On adjusted multivariable analysis in the RAPN cohort, omission of drain placement was associated with decreased LOS (β -0.45; 99.58% CI [-0.59, -0.32]) but no difference in overall complication rates. After adjusted analysis in the RARP cohort, omission of drain placement was associated with decreased risk of any complication (OR 0.73 [0.62–0.87]), infectious complication (OR 0.66 [0.49–0.89]), and LOS (β -0.30 [-0.37, -0.24]).

Conclusions

Using a large contemporary database, this study demonstrates that omission of drains during RAPN and RARP was safe without increased risk of postoperative complications. Despite inherent selection bias in this cohort, our data suggests that routine drain placement is not necessary for these procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProstatectomyRobotic Surgical ProceduresNephrectomyPostoperative ComplicationsDrainageHumansMaleMiddle AgedAgedIntraoperative CareFemaleRetrospective Studies

Stichwörter der Autor:innen

Intraperitoneal drainPostoperative complicationsRobotic partial nephrectomyRobotic prostatectomyUrologic oncology

Autor:innen und Institutionen

  • Section of Urologic Oncology, Rutgers Cancer Institute and Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA. jp2009@rwjms.rutgers.edu.
  • Section of Urologic Oncology, Rutgers Cancer Institute and Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA.
  • Department of Urology, University of California at San Francisco, San Francisco, CA, USA.
  • Division of Urologic Oncology, University of Michigan Rogel Cancer Center, Ann Arbor, MI, USA.

Förderung

  • NCI NIH HHS
  • National Cancer Institute

Zitieren

APA

Pfail, J., Drobner, J., Kaldany, A., Chua, K., Lichtbroun, B., Passarelli, R., Patel, H., Srivastava, A., Golombos, D., Jang, T. L., Packiam, V. T., & Ghodoussipour, S. (2024). Omission of intraoperative drain placement during robotic partial nephrectomy and robotic radical prostatectomy is safe: an analysis of 18,000 patients. World Journal of Urology. https://doi.org/10.1007/s00345-024-05320-7

Vancouver

Pfail J, Drobner J, Kaldany A, Chua K, Lichtbroun B, Passarelli R, et al. Omission of intraoperative drain placement during robotic partial nephrectomy and robotic radical prostatectomy is safe: an analysis of 18,000 patients. World Journal of Urology. 2024. doi:10.1007/s00345-024-05320-7

BibTeX
@article{Pfail2024,
  author = {Pfail, John and Drobner, Jake and Kaldany, Alain and Chua, Kevin and Lichtbroun, Benjamin and Passarelli, Rachel and Patel, Hiren and Srivastava, Arnav and Golombos, David and Jang, Thomas L and Packiam, Vignesh T and Ghodoussipour, Saum},
  title = {Omission of intraoperative drain placement during robotic partial nephrectomy and robotic radical prostatectomy is safe: an analysis of 18,000 patients},
  journal = {World Journal of Urology},
  year = {2024},
  doi = {10.1007/s00345-024-05320-7}
}
Kostenlos starten →