Illumination matters Part III: Impact of light obstruction on illuminance from flexible ureteroscopes — a comparative PEARLS analysis

Jia-Lun Kwok, Eugenio Ventimiglia, Vincent De Coninck, Alba Sierra, Frédéric Panthier, Mariela Corrales, Yazeed Barghouthy, Vineet Gauhar, Benedikt Kranzbühler, Florian Alexander Schmid, Cédric Poyet, Daniel Eberli und 2 weitere

World Journal of Urology · 2024

DOI: 10.1007/s00345-024-04910-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Urology, 2024. Verfasst von Jia-Lun Kwok und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 10, 8091, Zurich, Switzerland. Hauptthemen laut MEDLINE: Ureteroscopes, Lighting. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Zurich.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Artifacts from poor ureteroscopes’ light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model.

Methods

We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o’clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model.

Results

Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o’clock and 3 o’clock obstructive situation, respectively. At 100% brightness setting, these became 6 o’clock and 12 o’clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3.

Conclusions

Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

UreteroscopesLightingHumansEquipment DesignUrologistsDisposable EquipmentUreteroscopy

Stichwörter der Autor:innen

Background illuminanceFlexible ureteroscopyObstructionSalineSkew

Autor:innen und Institutionen

  • Department of Urology, University Hospital Zurich, University of Zurich, Frauenklinikstrasse 10, 8091, Zurich, Switzerland.
  • Department of Urology, Tan Tock Seng Hospital, Singapore, Singapore.
  • Progressive Endourological Association for Research and Leading Solutions (PEARLS), Paris, France.
  • Endourology and Urolithiasis Working Group, Young Academic Urologists (YAU), Arnhem, The Netherlands.
  • Division of Experimental Oncology/Unit of Urology, Urological Research Institute, IRCCS Ospedale San Raffaele, Milan, Italy.
  • Department of Urology, AZ Klina, Brasschaat, Belgium.

Förderung

  • University of Zurich

Zitieren

APA

Kwok, J. L., Ventimiglia, E., De Coninck, V., Sierra, A., Panthier, F., Corrales, M., Barghouthy, Y., Gauhar, V., Kranzbühler, B., Schmid, F. A., Poyet, C., Eberli, D., Traxer, O., & Keller, E. X. (2024). Illumination matters Part III: Impact of light obstruction on illuminance from flexible ureteroscopes — a comparative PEARLS analysis. World Journal of Urology. https://doi.org/10.1007/s00345-024-04910-9

Vancouver

Kwok JL, Ventimiglia E, De Coninck V, Sierra A, Panthier F, Corrales M, et al. Illumination matters Part III: Impact of light obstruction on illuminance from flexible ureteroscopes — a comparative PEARLS analysis. World Journal of Urology. 2024. doi:10.1007/s00345-024-04910-9

BibTeX
@article{Kwok2024,
  author = {Kwok, Jia-Lun and Ventimiglia, Eugenio and De Coninck, Vincent and Sierra, Alba and Panthier, Frédéric and Corrales, Mariela and Barghouthy, Yazeed and Gauhar, Vineet and Kranzbühler, Benedikt and Schmid, Florian Alexander and Poyet, Cédric and Eberli, Daniel and Traxer, Olivier and Keller, Etienne Xavier},
  title = {Illumination matters Part III: Impact of light obstruction on illuminance from flexible ureteroscopes — a comparative PEARLS analysis},
  journal = {World Journal of Urology},
  year = {2024},
  doi = {10.1007/s00345-024-04910-9}
}
Kostenlos starten →