Flexible determination of the nonlinear refractive index or pulse duration in the visible range using Z-scan-based technique: application to fused silica
Applied Physics B · 2025-07 · 131 (7)
DOI: 10.1007/s00340-025-08502-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Physics B, online erschienen am 14.06.2025. Verfasst von Georges Boudebs und 3 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: “Contrat de Plan État-Région” (CPER) program FEMTOMAT, Univ Angers, SFR MATRIX, Univ Angers, LPhiA.
Abstract (Originalsprache)
We present a flexible and cost-effective Z-scan-based method, referred to as Beam Size Relative Variation (BSRV), for the determination of either the nonlinear refractive index $${n}_{2}$$ n 2 or the femtosecond pulse duration τ in the visible spectral range (650–900 nm). The technique, implemented using a tunable optical parametric amplifier (OPA), accommodates arbitrary beam profiles, thus removing the constraints imposed by traditional Gaussian or circular symmetry assumptions. Spatial characterization is performed via CCD imaging, while temporal information can be inferred directly from Z-scan measurements when a reference material is used. As a proof of concept, the method is applied to fused silica, a widely used reference material in nonlinear optics. A total of 108 Z-scan measurements were conducted across the spectral range, allowing for a robust statistical analysis of the extracted parameters. A new reference value is established for fused silica: $$n_{2} = \left( {1.8 \pm 0.4} \right) \times 10^{ - 20} m^{2} /W$$ n 2 = 1.8 ± 0.4 × 10 - 20 m 2 / W . Notably, the pulse durations extracted from BSRV Z-scan data are statistically validated through independent measurements based on two-photon absorption (2PA) autocorrelation, with both methods revealing consistent spectral trends. All simulation tools and analysis codes are provided in the Supplementary Information to ensure reproducibility. This approach offers a reliable and accessible framework for nonlinear optical characterization, particularly in experimental contexts where conventional autocorrelation systems may be unavailable or cost prohibitive.
Förderung
- “Contrat de Plan État-Région” (CPER) program FEMTOMAT
- Univ Angers, SFR MATRIX
- Univ Angers, LPhiA
- Université d'Angers
Zitieren
APA
Boudebs, G., Zinoune, J., Cassagne, C., & Mauclair, C. (2025). Flexible determination of the nonlinear refractive index or pulse duration in the visible range using Z-scan-based technique: application to fused silica. Applied Physics B, 131(7). https://doi.org/10.1007/s00340-025-08502-2
Vancouver
Boudebs G, Zinoune J, Cassagne C, Mauclair C. Flexible determination of the nonlinear refractive index or pulse duration in the visible range using Z-scan-based technique: application to fused silica. Applied Physics B. 2025;131(7). doi:10.1007/s00340-025-08502-2
BibTeX
@article{Boudebs2025,
author = {Boudebs, Georges and Zinoune, Julien-Bilal and Cassagne, Christophe and Mauclair, Cyril},
title = {Flexible determination of the nonlinear refractive index or pulse duration in the visible range using Z-scan-based technique: application to fused silica},
journal = {Applied Physics B},
year = {2025},
volume = {131},
number = {7},
doi = {10.1007/s00340-025-08502-2}
}
EUVIMED