EUVIMEDEUVIMED entdecken
Vergleichsstudie

CT quantification of interstitial lung abnormalities: a prospective comparison between supine and prone positions

Yura Ahn, Sang Min Lee, Jung Im Kim, Kyung-Hyun Do, Jang Ho Lee, Ho Cheol Kim, Joon Beom Seo

European Radiology · 06.05.2026 · 36 (9) · 7186-7198

DOI: 10.1007/s00330-026-12595-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, online erschienen am 06.05.2026. Verfasst von Yura Ahn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung Diseases, Interstitial, Patient Positioning. Die Arbeit nennt 23 Literaturangaben. Gefördert von: National Research Foundation of Korea (NRF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To prospectively evaluate positional variability in quantitative CT (qCT)-derived measurements of interstitial lung abnormality (ILA) using the same-day supine and prone CT. MATERIALS AND METHODS: In this prospective study (February 2024-February 2025), participants with ILA underwent sequential non-contrast supine and prone CT scans using identical acquisition parameters. A commercially available deep learning-based software quantified fibrotic (reticulation and honeycombing) and nonfibrotic (ground-glass opacity) ILA components in accordance with Fleischner Society definitions. qCT differences between supine and prone measurements were assessed using paired t tests, Bland-Altman analysis with 95% limits of agreement (LOA), and concordance correlation coefficients (CCC). RESULTS: Of 47 consented participants, 38 (mean age, 70.9 ± 6.4 years; 27 men) were included in the final analysis. Mean total ILA extent was greater on supine than on prone scans (1.76% vs 1.39%, p = 0.02), largely due to a greater extent of fibrotic ILAs on supine images (1.43% vs 1.12%, p = 0.007). The 95% LOA between supine and prone scans were -1.49% to 2.23% for total ILA extent, -0.97% to 1.58% for the fibrotic component, and -0.89% to 1.03% for the nonfibrotic component. Agreement between positions was moderate for the fibrotic component (CCC = 0.770), and poor for the nonfibrotic component (CCC = 0.431), with the lowest reproducibility observed in dependent lung zones. CONCLUSION: The measurement variability of qCT result of ILA between supine and prone scans was approximately 1.9%, with moderate agreement for the fibrotic component but poor agreement for the nonfibrotic component between the same-day supine and prone CT scans. KEY POINTS: Question Whether qCT-derived measurements of ILA are interchangeable between supine and prone CT scans remains unknown. Findings qCT measurements showed approximately 1.9% positional variability, with moderate agreement for fibrotic components but poor agreement for nonfibrotic components, especially in dependent lung zones. Clinical relevance Supine and prone scans should not be used interchangeably for qCT analysis of ILA. Consistent patient positioning is essential to ensure accurate longitudinal assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedLung Diseases, InterstitialPatient PositioningHumansSupine PositionProne PositionMaleProspective StudiesFemaleAgedReproducibility of ResultsLung

Stichwörter der Autor:innen

BiasCTInterstitial lung abnormalityInterstitial lung diseaseQuantification

Autor:innen und Institutionen

  • Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
  • Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea. sangmin.lee.md@gmail.com.
  • Department of Pulmonary and Critical Care Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.

Förderung

  • National Research Foundation of Korea (NRF)

Zitieren

APA

Ahn, Y., Lee, S. M., Kim, J. I., Do, K. H., Lee, J. H., Kim, H. C., & Seo, J. B. (2026). CT quantification of interstitial lung abnormalities: a prospective comparison between supine and prone positions. European Radiology, 36(9), 7186-7198. https://doi.org/10.1007/s00330-026-12595-4

Vancouver

Ahn Y, Lee SM, Kim JI, Do KH, Lee JH, Kim HC, et al. CT quantification of interstitial lung abnormalities: a prospective comparison between supine and prone positions. European Radiology. 2026;36(9):7186-7198. doi:10.1007/s00330-026-12595-4

BibTeX
@article{Ahn2026,
  author = {Ahn, Yura and Lee, Sang Min and Kim, Jung Im and Do, Kyung-Hyun and Lee, Jang Ho and Kim, Ho Cheol and Seo, Joon Beom},
  title = {CT quantification of interstitial lung abnormalities: a prospective comparison between supine and prone positions},
  journal = {European Radiology},
  year = {2026},
  volume = {36},
  number = {9},
  pages = {7186--7198},
  doi = {10.1007/s00330-026-12595-4}
}
Kostenlos starten →