Assessing the feasibility of neonatal chest MRI for bronchopulmonary dysplasia using a standard 1.5-Tesla scanner
European Radiology · 24.03.2026 · 36 (8) · 6399-6409
DOI: 10.1007/s00330-026-12452-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, online erschienen am 24.03.2026. Verfasst von Jantine J Wisse und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, Department of Neonatal and Pediatric Intensive Care, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherl…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Bronchopulmonary Dysplasia. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stichting Vrienden van het Sophia.
Abstract (Originalsprache)
Objective
Accurate imaging is essential for assessing structural lung abnormalities in children with bronchopulmonary dysplasia (BPD). Chest MRI offers a radiation-free alternative to CT and enables silent scanning. This study aimed to develop and evaluate a chest MRI protocol for BPD using a standard 1.5-Tesla (T) MRI scanner with a dedicated neonatal chest coil. Materials and methods In this prospective pilot study, infants underwent feed-and-swaddle chest MRI at ~40 weeks postmenstrual age, and chest CT at six months corrected age. The MRI protocol included free-breathing axial T2-weighted (T2-W) fast spin echo (PROPELLER) and axial proton density-weighted (PD-W) gradient zero echo time (ZTE) sequences. Scans were assessed for image quality, and quantified for normal, hypo-/hyperintense lung tissue and bronchopathy. MRI and CT scores were correlated using Pearson’s or Spearman’s coefficients, based on data distribution.
Results
Eight infants participated (seven preterm < 28 weeks’ gestation with severe BPD; one term neonate with asphyxia). T2-w PROPELLER provided superior soft tissue contrast and fewer artefacts than ZTE. ZTE enabled silent scanning and better visualisation of hypointense structures. Quantitative scores were comparable between PROPELLER and ZTE sequences. Significant correlations were found between MRI and CT scores for normal and hyperintense lung tissue ( p < 0.05; r = 0.84–0.96), but not for hypointense regions and bronchopathy.
Conclusion
We developed a feasible and safe chest MRI protocol for imaging severe BPD-related lung abnormalities in neonates using a standard 1.5-T system. While technically promising, MRI is not yet clinically equivalent to CT. Further validation is needed to define its potential role in BPD assessment. Key Points Question Can a standard 1.5 T chest MRI protocol performed without anaesthesia reliably image lung abnormalities in neonates with BPD?
Findings
T2-W PROPELLER sequence provided superior image quality and fewer artefacts compared to the ZTE, especially in depicting fissures and bronchi . Clinical relevance Our BPD-MRI protocol enables safe, radiation-free lung imaging in neonates with severe BPD without requiring anaesthesia. It offers a technically feasible alternative to CT and may support early structural assessment before discharge in routine clinical care .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Neonatology, Department of Neonatal and Pediatric Intensive Care, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
- Department of Adult Intensive Care, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
- Division of Respiratory Medicine and Allergology, Department of Pediatrics, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands.
- Department of Radiology and Nuclear Medicine, Erasmus Medical Centre-Sophia Children's Hospital, Rotterdam, The Netherlands.
- Thirona B.V, Nijmegen, The Netherlands.
- Medical University Eppendorf, Medical Children's Hospital, Divison of Neonatology and Pediatric Intensive Care, Hamburg, Germany.
Förderung
- Stichting Vrienden van het Sophia
Zitieren
APA
Wisse, J. J., Elders, B. B. L. J., Bonte, M., Wielopolski, P. A., Kroon, A. A., Tiddens, H. A. W. M., Duijts, L., Pijnenburg, M. W. H., Reiss, I. K. M., & Ciet, P. (2026). Assessing the feasibility of neonatal chest MRI for bronchopulmonary dysplasia using a standard 1.5-Tesla scanner. European Radiology, 36(8), 6399-6409. https://doi.org/10.1007/s00330-026-12452-4
Vancouver
Wisse JJ, Elders BBLJ, Bonte M, Wielopolski PA, Kroon AA, Tiddens HAWM, et al. Assessing the feasibility of neonatal chest MRI for bronchopulmonary dysplasia using a standard 1.5-Tesla scanner. European Radiology. 2026;36(8):6399-6409. doi:10.1007/s00330-026-12452-4
BibTeX
@article{Wisse2026,
author = {Wisse, Jantine J and Elders, Bernadette B L J and Bonte, Merlijn and Wielopolski, Piotr A and Kroon, André A and Tiddens, Harm A W M and Duijts, Liesbeth and Pijnenburg, Mariëlle W H and Reiss, Irwin K M and Ciet, Pierluigi},
title = {Assessing the feasibility of neonatal chest MRI for bronchopulmonary dysplasia using a standard 1.5-Tesla scanner},
journal = {European Radiology},
year = {2026},
volume = {36},
number = {8},
pages = {6399--6409},
doi = {10.1007/s00330-026-12452-4}
}
EUVIMED