Temporal bone dual-layer detector dual-energy computed tomography for identifying cholesteatoma

Xiaoxue Fan, Changwei Ding, Sizhe Gao, Xiaomei Lu, Xiulan Ma, Yang Hou

European Radiology · 2025

DOI: 10.1007/s00330-025-11813-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, 2025. Verfasst von Xiaoxue Fan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Temporal Bone, Radiography, Dual-Energy Scanned Projection, Cholesteatoma, Middle Ear. Die Arbeit nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Cholesteatomas (CSs) are locally aggressive and can infiltrate adjacent structures as they expand. This study aimed to establish a straightforward scoring system using dual-layer detector dual-energy CT (DL-DECT) to improve the identification of cholesteatomas in patients. MATERIALS AND METHODS: Between August 2023 and July 2024, 871 patients with soft tissue density shadows in the ear region who underwent DL-DECT examination were retrospectively enrolled at our institute. Surgical treatments followed by pathological examinations were performed. Based on pathological findings, the lesions were classified into cholesteatoma (CS) and non-cholesteatoma (non-CS) groups. The diagnostic performance of anatomical and quantitative parameters derived from DL-DECT was evaluated using receiver operating characteristic (ROC) curve analysis. Logistic regression was applied to develop a diagnostic scoring system. RESULTS: A total of 87 patients (median age, 51 years; 45 men and 42 women) with suspected temporal bone CS were included, comprising 44 CS cases and 43 non-CS cases. The effective atomic number (Zeff) demonstrated the highest diagnostic accuracy (area under the curve [AUC] = 0.786), followed by the slope of the energy spectral curve (AUC = 0.784), scutum destruction (AUC = 0.759), and CT40 keV (AUC = 0.724). Logistic regression identified two significant predictors, which were incorporated into the scoring system. When the system score reached 2 points (Zeff ≤ 7.12 accompanied by scutum destruction), the AUC in the ROC analysis reached 0.868 (95% confidence interval: 0.778-0.931), significantly outperforming each individual parameter (all p < 0.05). CONCLUSION: The DL-DECT-derived scoring system serves as an innovative imaging marker for detecting CSs. KEY POINTS: Question Accurate differentiation between CSs and non-CSs is critical for selecting surgical approaches. However, high-resolution CT demonstrates limited discriminatory power. Findings A straightforward diagnostic scoring system incorporating Zeff ≤ 7.12 and scutum destruction was developed to efficiently identify patients with CS. Clinical relevance This scoring system may facilitate the early identification of CS, potentially improving patient outcomes through timely intervention.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedTemporal BoneRadiography, Dual-Energy Scanned ProjectionCholesteatoma, Middle EarHumansMaleFemaleMiddle AgedRetrospective StudiesAdultAgedAdolescentYoung Adult

Stichwörter der Autor:innen

CholesteatomaDual-energyEar diseasesMultidetector computed tomography

Autor:innen und Institutionen

  • Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
  • CT Clinical Science CT, Philips Healthcare, Shenyang, China.
  • Department of Otolaryngology Head and Neck Surgery, Shengjing Hospital of China Medical University, Shenyang, China. xiulan_ma1964@163.com.
  • Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China. houyang1973@163.com.

Zitieren

APA

Fan, X., Ding, C., Gao, S., Lu, X., Ma, X., & Hou, Y. (2025). Temporal bone dual-layer detector dual-energy computed tomography for identifying cholesteatoma. European Radiology. https://doi.org/10.1007/s00330-025-11813-9

Vancouver

Fan X, Ding C, Gao S, Lu X, Ma X, Hou Y. Temporal bone dual-layer detector dual-energy computed tomography for identifying cholesteatoma. European Radiology. 2025. doi:10.1007/s00330-025-11813-9

BibTeX
@article{Fan2025,
  author = {Fan, Xiaoxue and Ding, Changwei and Gao, Sizhe and Lu, Xiaomei and Ma, Xiulan and Hou, Yang},
  title = {Temporal bone dual-layer detector dual-energy computed tomography for identifying cholesteatoma},
  journal = {European Radiology},
  year = {2025},
  doi = {10.1007/s00330-025-11813-9}
}
Kostenlos starten →