EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Value of dual-energy computed tomography in the diagnosis of bowel ischemia in patients with mechanical small-bowel obstruction: a retrospective, dual-center study

Sébastien Mulé, Baptiste Brault, Maxime Blain, Nada Neifar, Caroline Touloupas, Isabelle Boulay-Coletta, Edouard Reizine, Alain Luciani, Marc Zins

European Radiology · 06.05.2025 · 35 (11) · 7320-7332

DOI: 10.1007/s00330-025-11635-9 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Radiology, online erschienen am 06.05.2025. Verfasst von Sébastien Mulé und 8 weiteren Autor:innen. Beteiligte Einrichtung: Medical Imaging Department, AP-HP, Henri Mondor University Hospital, 1 rue Gustave Eiffel, 94000, Créteil, France. sebastien.mule@aphp.fr. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Intestinal Obstruction, Ischemia, Intestine, Small. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To investigate the diagnostic value of rapid-kV-switching dual-energy CT (DECT) for identifying bowel ischemia in patients with mechanical small-bowel obstruction (SBO), compared to 120 kVp-equivalent CT. Materials and methods This retrospective dual-center study included 112 patients with mechanical SBO. Clinical and surgical outcomes with histological findings were recorded as the reference standard. Three readers independently reviewed true unenhanced (TUE) and portal-venous 77-keV virtual monoenergetic images (VMI) (dataset#1), virtual unenhanced (VUE), iodine, and 50-keV VMI (dataset#2). Ischemia was defined as the presence of at least two CT features among reduced bowel-wall enhancement, diffuse mesenteric haziness, and a closed-loop mechanism. Unenhanced bowel-wall attenuation was also analysed. Bowel-wall attenuation and iodine concentration were measured in involved loops and proximal dilated loops. Sensitivity and specificity were calculated for each CT feature. Association between iodine concentration and bowel ischemia was analysed using ROC curves.

Results

Forty-one (37%) patients underwent surgery. Twenty-four (21%) patients had findings of bowel ischemia, including 11 (10%) patients with irreversible ischemia (necrosis). Diagnostic performance for ischemia and necrosis was similar between both datasets for all readers ( p > 0.49 for ischemia and p = 1 for necrosis). Increased bowel-wall attenuation on VUE or TUE images had a non-significantly different diagnostic value for all readers ( p > 0.21 for ischemia and p > 0.78 for necrosis). Bowel-wall iodine concentration identified bowel necrosis with 82% sensitivity and 83% specificity (optimal cutoff value 1.82 mg/mL).

Conclusion

DECT performed similarly to 120 kVp-equivalent CT for the diagnosis of bowel ischemia in patients with mechanical SBO. VUE images offer a viable alternative to TUE images for the identification of increased bowel-wall attenuation. Bowel-wall iodine concentration accurately identifies bowel necrosis. Key Points Question Dual-energy CT (DECT) could detect small-bowel ischemia caused by mechanical small-bowel obstruction (SBO), but its performance is unknown .

Findings

Reduced bowel-wall enhancement and increased unenhanced bowel-wall attenuation were not significantly different between DECT and 120 kVp-equivalent CT. Bowel-wall iodine concentration identified necrosis with 82% sensitivity and 83% specificity . Clinical relevance DECT performed similarly to 120 kVp-equivalent CT in depicting bowel ischemia in patients with mechanical SBO, while adding quantitative analysis of bowel-wall iodine concentration may further help identify patients requiring surgery . Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedIntestinal ObstructionIschemiaIntestine, SmallRadiography, Dual-Energy Scanned ProjectionHumansMaleFemaleRetrospective StudiesMiddle AgedAgedSensitivity and SpecificityAged, 80 and overAdultContrast Media

Stichwörter der Autor:innen

Bowel ischemiaDual-energy CTIodineSmall-bowel obstruction

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Medical Imaging Department, AP-HP, Henri Mondor University Hospital, 1 rue Gustave Eiffel, 94000, Créteil, France. sebastien.mule@aphp.fr.
  • Faculty of Health, University of Paris Est Créteil, Créteil, France. sebastien.mule@aphp.fr.
  • INSERM IMRB, U 955, Team 18, Créteil, France. sebastien.mule@aphp.fr.
  • Medical Imaging Department, AP-HP, Henri Mondor University Hospital, 1 rue Gustave Eiffel, 94000, Créteil, France.
  • Faculty of Health, University of Paris Est Créteil, Créteil, France.
  • Department of Medical Imaging, Paris Saint Joseph Hospital, 185 rue Raymond Losserand, 75014, Paris, France.

Zitieren

APA

Mulé, S., Brault, B., Blain, M., Neifar, N., Touloupas, C., Boulay-Coletta, I., Reizine, E., Luciani, A., & Zins, M. (2025). Value of dual-energy computed tomography in the diagnosis of bowel ischemia in patients with mechanical small-bowel obstruction: a retrospective, dual-center study. European Radiology, 35(11), 7320-7332. https://doi.org/10.1007/s00330-025-11635-9

Vancouver

Mulé S, Brault B, Blain M, Neifar N, Touloupas C, Boulay-Coletta I, et al. Value of dual-energy computed tomography in the diagnosis of bowel ischemia in patients with mechanical small-bowel obstruction: a retrospective, dual-center study. European Radiology. 2025;35(11):7320-7332. doi:10.1007/s00330-025-11635-9

BibTeX
@article{Mul2025,
  author = {Mulé, Sébastien and Brault, Baptiste and Blain, Maxime and Neifar, Nada and Touloupas, Caroline and Boulay-Coletta, Isabelle and Reizine, Edouard and Luciani, Alain and Zins, Marc},
  title = {Value of dual-energy computed tomography in the diagnosis of bowel ischemia in patients with mechanical small-bowel obstruction: a retrospective, dual-center study},
  journal = {European Radiology},
  year = {2025},
  volume = {35},
  number = {11},
  pages = {7320--7332},
  doi = {10.1007/s00330-025-11635-9}
}
Kostenlos starten →