Deep learning and conventional hip MRI for the detection of labral and cartilage abnormalities using arthroscopy as standard of reference
European Radiology · 16.04.2025 · 35 (10) · 6065-6078
DOI: 10.1007/s00330-025-11546-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, online erschienen am 16.04.2025. Verfasst von Alexander W Marka und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, School of Medicine and Health & Klinikum rechts der Isar, Technical University of Munich, Muni…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Arthroscopy, Deep Learning, Femoracetabular Impingement. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To evaluate the performance of high-resolution deep learning-based hip MR imaging (CSAI) compared to standard-resolution compressed sense (CS) sequences using hip arthroscopy as standard of reference.
Methods
Thirty-two patients (mean age, 37.5 years (± 11.7), 24 men) with femoroacetabular impingement syndrome underwent 3-T MR imaging prior to hip arthroscopy. Coronal and sagittal intermediate-weighted TSE sequences with fat saturation were obtained using CS (0.6 × 0.8 mm) and high-resolution CSAI (0.3 × 0.4 mm), with 3 mm slice thickness and similar acquisition times (3:55–4:12 min). MR scans were independently assessed by three radiologists and a hip arthroscopy specialist for labral and cartilage abnormalities. Sensitivity, specificity, and accuracy were calculated using arthroscopy as reference standard. Statistical comparisons between CS and CSAI were performed using McNemar’s test.
Results
Labral abnormality detection showed excellent sensitivity for radiologists (CS and CSAI: 97–100%) and the surgeon (CS: 81%, CSAI: 90%, p = 0.08), with 100% specificity. Overall cartilage lesion sensitivity was significantly higher with CSAI versus CS (42% vs. 37%, p < 0.001). Highest sensitivity was observed in superolateral acetabular cartilage (CS: 81%, CSAI: 88%, p < 0.001), while highest specificity was found for the anteroinferior acetabular cartilage (CS and CSAI: 99%). Sensitivity was lowest for the assessment of the anteroinferior and posterior acetabular zones, and inferior and posterior femoral zones (CS and CSAI < 6%).
Conclusion
CS and CSAI MR imaging showed excellent diagnostic performance for labral abnormalities. Despite CSAI’s improved cartilage lesion detection, overall diagnostic performance for cartilage assessment remained suboptimal. Key Points Question Accurate preoperative detection of labral and cartilage lesions in femoroacetabular impingement remains challenging, with current MRI protocols showing variable diagnostic performance.
Findings
High-resolution deep learning-based and standard-resolution compressed sense MRI demonstrate comparable diagnostic performance, with high accuracy for labral defects but limited sensitivity for cartilage lesions. Clinical relevance Current MRI protocols, regardless of resolution optimization, show persistent limitations in cartilage evaluation, indicating the need for further technical advancement to improve diagnostic confidence in presurgical planning. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, School of Medicine and Health & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany. alexander.marka@tum.de.
- Department of Diagnostic and Interventional Radiology, School of Medicine and Health & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- Musculoskeletal Radiology Section, School of Medicine and Health & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- Philips GmbH, Hamburg, Germany.
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health & Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
Zitieren
APA
Marka, A. W., Meurer, F., Twardy, V., Graf, M., Weiss, K., Makowski, M. R., Karampinos, D. C., Neumann, J., Woertler, K., Banke, I. J., & Foreman, S. C. (2025). Deep learning and conventional hip MRI for the detection of labral and cartilage abnormalities using arthroscopy as standard of reference. European Radiology, 35(10), 6065-6078. https://doi.org/10.1007/s00330-025-11546-9
Vancouver
Marka AW, Meurer F, Twardy V, Graf M, Weiss K, Makowski MR, et al. Deep learning and conventional hip MRI for the detection of labral and cartilage abnormalities using arthroscopy as standard of reference. European Radiology. 2025;35(10):6065-6078. doi:10.1007/s00330-025-11546-9
BibTeX
@article{Marka2025,
author = {Marka, Alexander W and Meurer, Felix and Twardy, Vanessa and Graf, Markus and Weiss, Kilian and Makowski, Marcus R and Karampinos, Dimitrios C and Neumann, Jan and Woertler, Klaus and Banke, Ingo J and Foreman, Sarah C},
title = {Deep learning and conventional hip MRI for the detection of labral and cartilage abnormalities using arthroscopy as standard of reference},
journal = {European Radiology},
year = {2025},
volume = {35},
number = {10},
pages = {6065--6078},
doi = {10.1007/s00330-025-11546-9}
}
EUVIMED