Cancers not detected in one-view breast tomosynthesis screening—characteristics and reasons for non-detection
European Radiology · 2024
DOI: 10.1007/s00330-024-11278-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Kristin Johnson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Diagnostics, Department of Translational Medicine, Lund University, Skåne University Hospital, Malmö, Sweden. kristin.johnson@med.lu.se. Hauptthemen laut MEDLINE: Breast Neoplasms, Mammography. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ALF, Swedich Society of Medical Radiology.
Abstract (Originalsprache)
Objectives
Limited understanding exists regarding non-detected cancers in digital breast tomosynthesis (DBT) screening. This study aims to classify non-detected cancers into true or false negatives, compare them with true positives, and analyze reasons for non-detection. Materials and methods Conducted between 2010 and 2015, the prospective single-center Malmö Breast Tomosynthesis Screening Trial (MBTST) compared one-view DBT and two-view digital mammography (DM). Cancers not detected by DBT, i.e., interval cancers, those detected in the next screening round, and those only identified by DM, underwent a retrospective informed review by in total four breast radiologists. Reviewers classified cancers into true negative, false negative, or non-visible based on both DBT and DM findings and assessed radiographic appearances at screening and diagnosis, breast density, and reasons for non-detection. Statistics included the Pearson X 2 test.
Results
In total, 89 cancers were not detected with DBT in the MBTST; eight cancers were solely in the DM reading mode, 59 during subsequent DM screening rounds, and 22 interval cancers. The proportion of cancers classified as false negative was 25% (22/89) based on DBT, compared with 18% (14/81) based on DM screening. The primary reason for false negatives was normal-appearing density, 50% (11/22). False negatives exhibited lower rates of high breast density, 36% (8/22), compared with true positives, 61% (78/129), p = 0.04, and spiculated densities were less frequent in false negatives, 41% (9/22) compared with true positives, 68% (88/129), p = 0.01.
Conclusion
False negatives in one-view DBT screening commonly presented with spiculated features, but less frequently than true positives, and were missed or misinterpreted due to benign appearances. Key Points Question Cancers not detected in digital breast tomosynthesis screening, including false negatives, remain partly unexplored.
Findings
The most common reason behind false-negative cancers in a large screening trial was a normal-appearing density. Clinical relevance Recognizing the factors contributing to false negative findings in digital breast tomosynthesis screening is essential to further improve cancer detection. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radiology Diagnostics, Department of Translational Medicine, Lund University, Skåne University Hospital, Malmö, Sweden. kristin.johnson@med.lu.se.
- Department of Imaging and Physiology, Skåne University Hospital, Malmö, Sweden. kristin.johnson@med.lu.se.
- Department of Radiology, Stanford University School of Medicine, Stanford, CA, USA.
- Radiology Diagnostics, Department of Translational Medicine, Lund University, Skåne University Hospital, Malmö, Sweden.
- Unilabs Mammography Unit, Skåne University Hospital, Malmö, Sweden.
- Department of Imaging and Physiology, Skåne University Hospital, Malmö, Sweden.
Förderung
- ALF
- Swedich Society of Medical Radiology
Zitieren
APA
Johnson, K., Ikeda, D. M., Andersson, I., & Zackrisson, S. (2024). Cancers not detected in one-view breast tomosynthesis screening—characteristics and reasons for non-detection. European Radiology. https://doi.org/10.1007/s00330-024-11278-2
Vancouver
Johnson K, Ikeda DM, Andersson I, Zackrisson S. Cancers not detected in one-view breast tomosynthesis screening—characteristics and reasons for non-detection. European Radiology. 2024. doi:10.1007/s00330-024-11278-2
BibTeX
@article{Johnson2024,
author = {Johnson, Kristin and Ikeda, Debra M and Andersson, Ingvar and Zackrisson, Sophia},
title = {Cancers not detected in one-view breast tomosynthesis screening—characteristics and reasons for non-detection},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-11278-2}
}
EUVIMED