PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1
European Radiology · 29.11.2024 · 35 (6) · 3096-3104
DOI: 10.1007/s00330-024-11233-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, online erschienen am 29.11.2024. Verfasst von Kang-Lung Lee und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Cambridge, Cambridge, UK. Hauptthemen laut MEDLINE: Prostate, Prostatic Neoplasms, Software, Multiparametric Magnetic Resonance Imaging. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIHR Cambridge Biomedical Research Centre.
Abstract (Originalsprache)
Objectives
Prostate imaging quality (PI-QUAL) was developed to standardise the evaluation of prostate MRI quality and has recently been updated to version 2. This study aims to assess inter-reader agreement for PI-QUAL v1 and v2 scores and investigates changes in MRI quality score categories. Materials and methods The study retrospectively analysed 350 multiparametric MRI (mpMRI) scans. Two expert uroradiologists independently assessed mpMRI quality using PI-QUAL v1 and v2 guidelines. Biparametric MRI (bpMRI) categorisation based on PI-QUAL v2 included only T2WI and diffusion-weighted imaging (DWI) results. Inter-reader agreement was determined using percentage agreement and kappa, and categorisation comparisons were made using the chi-square test.
Results
Substantial inter-reader agreement was observed for the overall PI-QUAL v1 score ( κ = 0.64) and moderate agreement for v2 mpMRI ( κ = 0.54) and v2 bpMRI scores ( κ = 0.57). Inter-reader agreements on individual sequences were similar between v1 and v2 (kappa for individual sequences: T2WI, 0.46 and 0.49; DWI, 0.66 and 0.70; DCE, 0.71 and 0.61). Quality levels shifted from predominantly “optimal” in v1 (65%) down to “acceptable” using v2 (55%); p < 0.001. The addition of DCE increased the proportion of cases with at least “adequate” quality at mpMRI (64%) compared to bpMRI (30%); p < 0.001.
Conclusion
This study shows consistent inter-reader agreement between PI-QUAL v1 and v2, encompassing overall and individual sequence categorisation. A notable shift from “optimal” to “acceptable” quality was demonstrated when moving from v1 to v2, with DCE tending improving quality from “inadequate” (bpMRI) to “acceptable” (mpMRI). Key Points Question What are the agreement levels of image quality of prostate MRI by using PI-QUAL v1 and v2?
Findings
Inter-reader agreement based on PI-QUAL v1 and v2 is comparable. Dynamic contrast enhancement (DCE) enables an overall shift from inadequate quality (at bpMRI) to acceptable quality (mpMRI). Clinical relevance The inter-reader agreement on PI-QUAL v1 and v2 is equivalent. PI-QUAL v2 assesses prostate bpMRI as well as mpMRI quality. Transitioning from inadequate to acceptable between v2-bpMRI and v2-mpMRI highlights the role of DCE as an “image quality safety net.”
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Cambridge, Cambridge, UK.
- Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK.
- Division of biostatistics and data science, Institute of Public Health, National Yang Ming Chiao Tung University, Taipei, Taiwan.
- Department of Emergency Medicine, Taipei Veterans General Hospital, Taipei, Taiwan.
Förderung
- NIHR Cambridge Biomedical Research Centre
Zitieren
APA
Lee, K. L., Caglic, I., Liao, P. H., Kessler, D. A., Guo, C. Y., & Barrett, T. (2024). PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1. European Radiology, 35(6), 3096-3104. https://doi.org/10.1007/s00330-024-11233-1
Vancouver
Lee KL, Caglic I, Liao PH, Kessler DA, Guo CY, Barrett T. PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1. European Radiology. 2024;35(6):3096-3104. doi:10.1007/s00330-024-11233-1
BibTeX
@article{Lee2024,
author = {Lee, Kang-Lung and Caglic, Iztok and Liao, Po-Hsiang and Kessler, Dimitri A and Guo, Chao-Yu and Barrett, Tristan},
title = {PI-QUAL version 2 image quality categorisation and inter-reader agreement compared to version 1},
journal = {European Radiology},
year = {2024},
volume = {35},
number = {6},
pages = {3096--3104},
doi = {10.1007/s00330-024-11233-1}
}
EUVIMED