Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis
European Radiology · 2024
DOI: 10.1007/s00330-024-11205-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Meng Li und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rheumatology and Immunology, Nanfang Hospital, Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Arthritis, Gouty, Tomography, X-Ray Computed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Guangzhou Science and Technology Fund, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
OBJECTIVES: This study aimed to compare the performance of different dual-energy computed tomography (DECT) technologies in detecting monosodium urate (MSU) crystals and evaluate the potential clinical value of novel second-generation dual-layer spectral detector CT (dlDECT) in gouty arthritis. METHODS: Using data collected from a tertiary hospital, we examined the diagnostic accuracy of different DECT technologies for the diagnosis of MSU. We used two standards: (1) demonstration of MSU crystals in synovial fluid (gold) and (2) 2015 ACR/EULAR gout classification criteria (silver). Furthermore, six novel spectral parameters derived from dlDECT were quantitatively calculated and analyzed for MSU diagnostic efficiency. RESULTS: Of the 243 patients with 387 joints, 68 (27.98%) had synovial fluid analysis. Compared with the gold standard, MSU diagnostic accuracy statistics for dlDECT, dual-source DECT (dsDECT) and rapid kilovolt peak switching DECT (rsDECT) were as follows: area under the curve (AUC): 0.85, 0.80 and 0.75, respectively. Findings were replicated compared with the silver standard. Multiparametric analysis in dlDECT demonstrated the highest MSU detection rate (92.86%), significantly higher than rsDECT (42.08%) and dsDECT (85.80%). Among novel parameters in dlDECT, Calcium-suppressed index 25 (CaSupp-I 25) exhibited the best performance in distinguishing materials (MSU, muscle, and bone), with an AUC of 0.992. The differentiation was also aided by histograms, scatter plots, and attenuation curves. CONCLUSION: The novel dlDECT is likely not inferior to other DECT technologies in MSU detection, especially its spectral parameter CaSupp-I 25. Multiparameter analysis showed the potential value for detecting MSU crystals in gouty arthritis, providing valuable clinical insights for gout diagnosis. KEY POINTS: Question The performance of different DECT technologies in detecting monosodium urate (MSU), and the value of dual-layer spectral detector CT (dlDECT) in gouty arthritis remains unclear. Findings The dlDECT was likely not inferior to other DECT technologies in MSU detection, and its multiparametric analysis provided valuable information for MSU diagnosis. Clinical relevance Novel dlDECT may improve the accurate detection of MSU crystals in gouty arthritis compared to other DECT technologies, providing valuable clinical insights and potentially improving patient outcomes for more precise gout diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Rheumatology and Immunology, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Department of Traditional Chinese Internal Medicine, School of Traditional Chinese Medicine, Southern Medical University, Guangzhou, China.
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China.
- Philips (China) Investment Co. Ltd., Guangzhou, China.
- Department of Rheumatology and Immunology, Nanfang Hospital, Southern Medical University, Guangzhou, China. lijuan@smu.edu.cn.
- Department of Traditional Chinese Internal Medicine, School of Traditional Chinese Medicine, Southern Medical University, Guangzhou, China. lijuan@smu.edu.cn.
Förderung
- Guangzhou Science and Technology Fund
- Basic and Applied Basic Research Foundation of Guangdong Province
Zitieren
APA
Li, M., Zhang, H., Liu, J. N., Zhong, F., Zheng, S. Y., Zhang, J., Chen, S. X., Lin, R. F., Zhang, K. Y., Liu, X. M., Xu, Y. K., & Li, J. (2024). Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis. European Radiology. https://doi.org/10.1007/s00330-024-11205-5
Vancouver
Li M, Zhang H, Liu JN, Zhong F, Zheng SY, Zhang J, et al. Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis. European Radiology. 2024. doi:10.1007/s00330-024-11205-5
BibTeX
@article{Li2024,
author = {Li, Meng and Zhang, Hui and Liu, Jia-Ni and Zhong, Fei and Zheng, Song-Yuan and Zhang, Jing and Chen, Shi-Xian and Lin, Rui-Feng and Zhang, Kang-Yu and Liu, Xiao-Min and Xu, Yi-Kai and Li, Juan},
title = {Performance of novel multiparametric second-generation dual-layer spectral detector CT in gouty arthritis},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-11205-5}
}
EUVIMED