Magnetization-transfer flow-independent dark-blood delayed enhancement cardiac MRI optimizes discrimination of ST-elevation myocardial infarct borders
European Radiology · 2024
DOI: 10.1007/s00330-024-11192-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Paulina Poskaite und 9 weiteren Autor:innen. Beteiligte Einrichtung: University Clinic of Radiology, Medical University of Innsbruck, A-6020, Innsbruck, Austria. Hauptthemen laut MEDLINE: ST Elevation Myocardial Infarction, Magnetic Resonance Imaging, Image Enhancement, Myocardial Infarction. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To prospectively compare image quality and infarct sizing methods between magnetization-transfer “flow-independent dark-blood delayed enhancement” (MT-FIDDLE) and standard “bright-blood”-late gadolinium enhancement (LGE) cardiac-magnetic-resonance (CMR) sequence. Methods “Bright-blood”-LGE and MT-FIDDLE sequence were acquired in 110 patients at 4 days ( n = 33), 4 months ( n = 39) and 12 months ( n = 38) after acute ST-elevation myocardial infarction (STEMI). Subjective image quality, including confidence in infarct segmentation and blood-pool bordering, were each rated on a 4-point Likert scale. Objective image quality was assessed by the detectability index (DI). Infarct volumes derived via full-width at half-maximum (FWHM) and different number of standard deviations (“n-SD”) methods on MT-FIDDLE images were compared with FWHM and reference 5-SD results from “bright-blood-LGE images.
Results
Overall subjective median image quality was excellent for both LGE sequences. Qualitative analysis revealed a significantly higher confidence in infarct segmentation and in blood-pool bordering for MT-FIDDLE as compared to “bright-blood”-LGE (all p < 0.001). Infarct volumes assessed by the FWHM technique on MT-FIDDLE and “bright-blood”-LGE showed excellent agreement overall (Concordance correlation coefficient, CCC = 0.96). The 3-SD technique for MT-FIDDLE showed the best agreement with the 5-SD method for “bright-blood”-LGE overall (CCC = 0.94), as well as in the subgroup with excellent confidence in infarct segmentation on “bright-blood”-LGE (CCC = 0.96). DI of scar versus LV blood-pool was higher for MT-FIDDLE (8.9 ± 5.5) compared to “bright-blood”-LGE sequence (2.0 ± 1.5; p < 0.001).
Conclusion
MT-FIDDLE significantly optimizes the discrimination between myocardial infarction and adjacent blood-pool in STEMI patients. As compared to the established 5-SD technique on “bright-blood”-LGE, the 3-SD method on MT-FIDDLE results in consistent infarct volumes. Key Points Question Does magnetization-transfer “flow-independent dark-blood delayed enhancement” (MT-FIDDLE) offer any benefits over standard “bright-blood”-late gadolinium enhancement (LGE) cardiac-magnetic-resonance (CMR) for identifying STEMI infarct borders?
Findings
MT-FIDDLE image quality was higher than LGE CMR and measured infarct volume comparability to the standard 5-SD-threshold-technique. Clinical relevance MT-FIDDLE facilitates the assessment of myocardial infarctions at the subendocardial border, improving the discrimination between myocardial infarction and adjacent blood-pool in STEMI patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University Clinic of Radiology, Medical University of Innsbruck, A-6020, Innsbruck, Austria.
- University Clinic of Radiology, Medical University of Innsbruck, A-6020, Innsbruck, Austria. christian.kremser@i-med.ac.at.
- Research and Development, Siemens Healthcare Diagnostics GmbH, A-8054, Graz, Austria.
- University Clinic of Internal Medicine III, Cardiology and Angiology, Medical University of Innsbruck, A-6020, Innsbruck, Austria.
- Siemens Medical Solutions, Malvern, Pennsylvania, US.
- Duke Cardiovascular Magnetic Resonance Center, Duke University Medical Center, Durham, North Carolina, US.
Zitieren
APA
Poskaite, P., Kremser, C., Pamminger, M., Troger, F., Reiter, G., Reinstadler, S. J., Metzler, B., Rehwald, W. G., Kim, R. J., & Mayr, A. (2024). Magnetization-transfer flow-independent dark-blood delayed enhancement cardiac MRI optimizes discrimination of ST-elevation myocardial infarct borders. European Radiology. https://doi.org/10.1007/s00330-024-11192-7
Vancouver
Poskaite P, Kremser C, Pamminger M, Troger F, Reiter G, Reinstadler SJ, et al. Magnetization-transfer flow-independent dark-blood delayed enhancement cardiac MRI optimizes discrimination of ST-elevation myocardial infarct borders. European Radiology. 2024. doi:10.1007/s00330-024-11192-7
BibTeX
@article{Poskaite2024,
author = {Poskaite, Paulina and Kremser, Christian and Pamminger, Mathias and Troger, Felix and Reiter, Gert and Reinstadler, Sebastian J and Metzler, Bernhard and Rehwald, Wolfgang G and Kim, Raymond J and Mayr, Agnes},
title = {Magnetization-transfer flow-independent dark-blood delayed enhancement cardiac MRI optimizes discrimination of ST-elevation myocardial infarct borders},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-11192-7}
}
EUVIMED