Impact of intensity standardisation and ComBat batch size on clinical-radiomic prognostic models performance in a multi-centre study of patients with glioblastoma

Kavi Fatania, Russell Frood, Hitesh Mistry, Susan C Short, James O'Connor, Andrew F Scarsbrook, Stuart Currie

European Radiology · 2024

DOI: 10.1007/s00330-024-11168-7 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Radiology, 2024. Verfasst von Kavi Fatania und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Leeds Teaching Hospitals NHS Trust, England, UK. Kavi.fatania@nhs.net. Hauptthemen laut MEDLINE: Glioblastoma, Brain Neoplasms, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Research UK, Leeds Hospitals Charity, Wellcome Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the effect of different intensity standardisation techniques (ISTs) and ComBat batch sizes on radiomics survival model performance and stability in a heterogenous, multi-centre cohort of patients with glioblastoma (GBM).

Methods

Multi-centre pre-operative MRI acquired between 2014 and 2020 in patients with IDH-wildtype unifocal WHO grade 4 GBM were retrospectively evaluated. WhiteStripe (WS), Nyul histogram matching (HM), and Z -score (ZS) ISTs were applied before radiomic feature (RF) extraction. RFs were realigned using ComBat and minimum batch size (MBS) of 5, 10, or 15 patients. Cox proportional hazards models for overall survival (OS) prediction were produced using five different selection strategies and the impact of IST and MBS was evaluated using bootstrapping. Calibration, discrimination, relative explained variation, and model fit were assessed. Instability was evaluated using 95% confidence intervals (95% CIs), feature selection frequency and calibration curves across the bootstrap resamples.

Results

One hundred ninety-five patients were included. Median OS = 13 (95% CI: 12–14) months. Twelve to fourteen unique MRI protocols were used per MRI sequence. HM and WS produced the highest relative increase in model discrimination, explained variation and model fit but IST choice did not greatly impact on stability, nor calibration. Larger ComBat batches improved discrimination, model fit, and explained variation but higher MBS (reduced sample size) reduced stability (across all performance metrics) and reduced calibration accuracy.

Conclusion

Heterogenous, real-world GBM data poses a challenge to the reproducibility of radiomics. ComBat generally improved model performance as MBS increased but reduced stability and calibration. HM and WS tended to improve model performance. Key Points Question ComBat harmonisation of RFs and intensity standardisation of MRI have not been thoroughly evaluated in multicentre, heterogeneous GBM data .

Findings

The addition of ComBat and ISTs can improve discrimination, relative model fit, and explained variance but degrades the calibration and stability of survival models . Clinical relevance Radiomics risk prediction models in real-world, multicentre contexts could be improved by ComBat and ISTs, however, this degrades calibration and prediction stability and this must be thoroughly investigated before patients can be accurately separated into different risk groups .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlioblastomaBrain NeoplasmsMagnetic Resonance ImagingHumansMaleFemaleMiddle AgedPrognosisRetrospective StudiesAgedAdultRadiomics

Stichwörter der Autor:innen

Brain neoplasmsDiagnostic imagingGlioblastomaPrognosisRadiomics

Autor:innen und Institutionen

  • Department of Radiology, Leeds Teaching Hospitals NHS Trust, England, UK. Kavi.fatania@nhs.net.
  • Leeds Institute of Medical Research, University of Leeds, Leeds, UK. Kavi.fatania@nhs.net.
  • Department of Radiology, Leeds Teaching Hospitals NHS Trust, England, UK.
  • Leeds Institute of Medical Research, University of Leeds, Leeds, UK.
  • Division of Cancer Sciences, University of Manchester, Manchester, UK.
  • Department of Oncology, Leeds Teaching Hospitals NHS Trust, England, UK.

Förderung

  • Cancer Research UK
  • Leeds Hospitals Charity
  • Wellcome Trust

Zitieren

APA

Fatania, K., Frood, R., Mistry, H., Short, S. C., O'Connor, J., Scarsbrook, A. F., & Currie, S. (2024). Impact of intensity standardisation and ComBat batch size on clinical-radiomic prognostic models performance in a multi-centre study of patients with glioblastoma. European Radiology. https://doi.org/10.1007/s00330-024-11168-7

Vancouver

Fatania K, Frood R, Mistry H, Short SC, O'Connor J, Scarsbrook AF, et al. Impact of intensity standardisation and ComBat batch size on clinical-radiomic prognostic models performance in a multi-centre study of patients with glioblastoma. European Radiology. 2024. doi:10.1007/s00330-024-11168-7

BibTeX
@article{Fatania2024,
  author = {Fatania, Kavi and Frood, Russell and Mistry, Hitesh and Short, Susan C and O'Connor, James and Scarsbrook, Andrew F and Currie, Stuart},
  title = {Impact of intensity standardisation and ComBat batch size on clinical-radiomic prognostic models performance in a multi-centre study of patients with glioblastoma},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-11168-7}
}
Kostenlos starten →