EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Breast density effect on the sensitivity of digital screening mammography in a UK cohort

Nicholas R Payne, Sarah E Hickman, Richard Black, Andrew N Priest, Sue Hudson, Fiona J Gilbert

European Radiology · 17.07.2024 · 35 (1) · 177-187

DOI: 10.1007/s00330-024-10951-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, online erschienen am 17.07.2024. Verfasst von Nicholas R Payne und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Cambridge School of Clinical Medicine, Box 218, Level 5, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK. Hauptthemen laut MEDLINE: Mammography, Breast Neoplasms, Breast Density, Sensitivity and Specificity. Die Arbeit wurde bisher 58-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To assess the performance of breast cancer screening by category of breast density and age in a UK screening cohort.

Methods

Raw full-field digital mammography data from a single site in the UK, forming a consecutive 3-year cohort of women aged 50 to 70 years from 2016 to 2018, were obtained retrospectively. Breast density was assessed using Volpara software. Examinations were grouped by density category and age group (50–60 and 61–70 years) to analyse screening performance. Statistical analysis was performed to determine the association between density categories and age groups. Volumetric breast density was assessed as a binary classifier of interval cancers (ICs) to find an optimal density threshold.

Results

Forty-nine thousand nine-hundred forty-eight screening examinations (409 screen-detected cancers (SDCs) and 205 ICs) were included in the analysis. Mammographic sensitivity, SDC/(SDC + IC), decreased with increasing breast density from 75.0% for density a ( p = 0.839, comparisons made to category b), to 73.5%, 59.8% ( p = 0.001), and 51.3% ( p < 0.001) in categories b, c, and d, respectively. IC rates were highest in the densest categories with rates of 1.8 ( p = 0.039), 3.2, 5.7 ( p < 0.001), and 7.9 ( p < 0.001) per thousand for categories a, b, c, and d, respectively. The recall rate increased with breast density, leading to more false positive recalls, especially in the younger age group. There was no significant difference between the optimal density threshold found, 6.85, and that Volpara defined as the b/c boundary, 7.5.

Conclusions

The performance of screening is significantly reduced with increasing density with IC rates in the densest category four times higher than in women with fatty breasts. False positives are a particular issue for the younger subgroup without prior examinations. Clinical relevance statement In women attending screening there is significant underdiagnosis of breast cancer in those with dense breasts, most marked in the highest density category but still three times higher than in women with fatty breasts in the second highest category. Key Points Breast density can mask cancers leading to underdiagnosis on mammography. Interval cancer rate increased with breast density categories ‘a’ to ‘d’; 1.8 to 7.9 per thousand. Recall rates increased with increasing breast density, leading to more false positive recalls.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MammographyBreast NeoplasmsBreast DensitySensitivity and SpecificityEarly Detection of CancerHumansFemaleMiddle AgedAgedUnited KingdomRetrospective StudiesCohort StudiesMass ScreeningAge Factors

Stichwörter der Autor:innen

Digital mammographyEarly detection of cancerMammographic breast density

Autor:innen und Institutionen

  • Department of Radiology, University of Cambridge School of Clinical Medicine, Box 218, Level 5, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
  • Department of Radiology, Barts Health NHS Trust, The Royal London Hospital, 80 Newark Street, London, E1 2ES, UK.
  • Department of Radiology, Addenbrookes Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
  • Peel and Schriek Consulting Limited, London, UK.
  • Department of Radiology, University of Cambridge School of Clinical Medicine, Box 218, Level 5, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK. fjg28@medschl.cam.ac.uk.
  • Department of Radiology, Addenbrookes Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK. fjg28@medschl.cam.ac.uk.

Zitieren

APA

Payne, N. R., Hickman, S. E., Black, R., Priest, A. N., Hudson, S., & Gilbert, F. J. (2024). Breast density effect on the sensitivity of digital screening mammography in a UK cohort. European Radiology, 35(1), 177-187. https://doi.org/10.1007/s00330-024-10951-w

Vancouver

Payne NR, Hickman SE, Black R, Priest AN, Hudson S, Gilbert FJ. Breast density effect on the sensitivity of digital screening mammography in a UK cohort. European Radiology. 2024;35(1):177-187. doi:10.1007/s00330-024-10951-w

BibTeX
@article{Payne2024,
  author = {Payne, Nicholas R and Hickman, Sarah E and Black, Richard and Priest, Andrew N and Hudson, Sue and Gilbert, Fiona J},
  title = {Breast density effect on the sensitivity of digital screening mammography in a UK cohort},
  journal = {European Radiology},
  year = {2024},
  volume = {35},
  number = {1},
  pages = {177--187},
  doi = {10.1007/s00330-024-10951-w}
}
Kostenlos starten →