Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT

Chen Pan, Tao Yu, Heng Zhao, Jiani He, Xiaomei Lu, Haiyan Tang, Yang Hong, Chao Shang, Qijun Wu, Aoran Yang, Chunli Li, Minghui Zhou und 1 weitere

European Radiology · 2024

DOI: 10.1007/s00330-024-10850-0 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Radiology, 2024. Verfasst von Chen Pan und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China. Hauptthemen laut MEDLINE: Contrast Media, Tomography, X-Ray Computed, Pancreas. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Liaoning Revitalization Talents Program, General Program of Liaoning Provincial Education Department.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To establish normative values and identify potential factors influencing pancreatic iodine uptake using dual-energy CT (DECT). MATERIALS AND METHODS: This retrospective study included participants without pancreatic diseases undergoing DECT at two institutions with different platforms. Their protocols both included arterial phase (AP), portal venous phase (PP), and equilibrium phase (EP), defined as 35 s-40 s, 60 s-70 s, and 150 s-180 s after injection of contrast agent, respectively. Both iodine concentration (IC) and normalised IC (NIC) were measured. Demographic features, local measurements of the pancreas and visceral fat area (VFA) were considered as potential factors influencing iodine uptake using multivariate linear regression analyses. RESULTS: A total of 562 participants (median age 58 years [interquartile range: 47-67], with 282 men) were evaluated. The mean IC differed significantly between two institutions (all p 0.05). The mean values of NIC were 0.22 at AP, 0.43 at PP and 0.45 at EP. NICAP was independently affected by VFA (β = 0.362, p < 0.001), smoking (β = -0.240, p = 0.001), and type-II diabetes (β = -0.449, p < 0.001); NICPP by VFA (β = -0.301, p = 0.017) and smoking (β = -0.291, p < 0.001); and NICEP by smoking (β = -0.154, p = 0.10) and alcohol consumption (β = -0.350, p < 0.001) with statistical power values over 0.81. CONCLUSION: NIC values were consistent across institutions. Abdominal obesity, smoking, alcohol consumption, and diabetes are independent factors influencing pancreatic iodine uptake. CLINICAL RELEVANCE STATEMENT: This study has provided reference normative values, influential factors and effective normalisation methods of pancreatic iodine uptake in multiphase dual-energy CT for future studies in this area as a new biological marker. KEY POINTS: Evaluation of pancreatic iodine uptake measured by dual-energy CT is a promising method for future studies. Abdominal obesity, smoking, alcohol consumption, diabetes, and sex are independent factors influencing pancreatic iodine uptake. Utility of normalised iodine concentration is necessary to ensure the consistency across different institutions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaTomography, X-Ray ComputedPancreasHumansMaleFemaleMiddle AgedRetrospective StudiesAgedRadiography, Dual-Energy Scanned ProjectionIodineReference Values

Stichwörter der Autor:innen

AdultDual energy CTMultidetector CTPancreasPancreatic iodine concentration

Substanzen

Contrast MediaIodine

Autor:innen und Institutionen

  • Department of Radiology, Shengjing Hospital of China Medical University, Shenyang, China.
  • Department of Radiology, The First Affiliated Hospital of University of South China, Hengyang, China.
  • CT Clinical Science CT, Philips Healthcare, Shenyang, China.
  • Department of Neurosurgery, Shengjing Hospital, China Medical University, Shenyang, China.
  • Department of Neurobiology, School of Life Sciences, China Medical University, Shenyang, China.
  • Department of Clinical Epidemiology, Shengjing Hospital of China Medical University, Shenyang, China.

Förderung

  • National Natural Science Foundation of China
  • Liaoning Revitalization Talents Program
  • General Program of Liaoning Provincial Education Department

Zitieren

APA

Pan, C., Yu, T., Zhao, H., He, J., Lu, X., Tang, H., Hong, Y., Shang, C., Wu, Q., Yang, A., Li, C., Zhou, M., & Shi, Y. (2024). Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT. European Radiology. https://doi.org/10.1007/s00330-024-10850-0

Vancouver

Pan C, Yu T, Zhao H, He J, Lu X, Tang H, et al. Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT. European Radiology. 2024. doi:10.1007/s00330-024-10850-0

BibTeX
@article{Pan2024,
  author = {Pan, Chen and Yu, Tao and Zhao, Heng and He, Jiani and Lu, Xiaomei and Tang, Haiyan and Hong, Yang and Shang, Chao and Wu, Qijun and Yang, Aoran and Li, Chunli and Zhou, Minghui and Shi, Yu},
  title = {Evaluation of pancreatic iodine uptake and related influential factors in multiphase dual-energy CT},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10850-0}
}
Kostenlos starten →