Bronchial artery embolization using small particles is safe and effective: a single center 12-year experience
European Radiology · 11.06.2024 · 34 (12) · 7786-7794
DOI: 10.1007/s00330-024-10836-y ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, online erschienen am 11.06.2024. Verfasst von Frances Sheehan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Imaging Department, Imperial College Healthcare NHS Trust, London, UK. Hauptthemen laut MEDLINE: Embolization, Therapeutic, Hemoptysis, Bronchial Arteries, Polyvinyl Alcohol. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Infrastructure support for this research was provided by the NIHR Imperial Biomedical Research Centre (BRC)..
Abstract (Originalsprache)
Background
Bronchial artery embolization (BAE) using particles is an established treatment for hemoptysis. The use of polyvinyl alcohol (PVA) with a particle size of 300 µm or larger is thought to reduce the risk of non-target embolization but may result in more proximal vessel occlusion than is ideal, resulting in a high rate of early recurrent hemorrhage.
Objective
This study evaluates the safety and efficacy of BAE using PVA particles with a size of less than 300 µm.
Methods
All patients who underwent BAE between 2010 and 2022 at a tertiary center were included. Demographic data, etiology and volume of hemoptysis, technical and clinical success, procedure-related complications, and follow-up information were collected from patients’ electronic records. 150–250 µm PVA particles were used to commence embolization in all patients with the subsequent use of larger-sized particles in some individuals. The Kaplan–Meier method was used to estimate recurrence and survival rates.
Results
One hundred forty-four patients underwent 189 embolization procedures between 2010 and 2022 and were followed up for a median of 35 months [IQR 19–89]. 150 µm to 250 µm PVA particles were used as the sole embolic agent in 137 cases. Hemoptysis recurred within 30 days in 7%. The median time to repeat intervention was 144 days [IQR 42–441]. Seventeen out of 144 patients had a pulmonary artery branch pseudoaneurysm. The rate of major complications was 1% with no instances of stroke or spinal artery ischemia. Thirty-day mortality was 2% (4/189).
Conclusion
BAE using 150–250 µm PVA particles is safe and effective with few complications and low rates of early hemoptysis recurrence. Clinical relevance statement BAE using small particles is likely to improve outcomes, particularly the rate of early recurrence, in patients with hemoptysis, without an increase in procedural complications. Key Points BAE is a safe and effective treatment for patients with hemoptysis . Using small PVA particles in BAE has few complications and low rates of early recurrence . Pulmonary artery pseudoaneurysms should be actively sought in those with hemoptysis undergoing BAE .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Imaging Department, Imperial College Healthcare NHS Trust, London, UK.
- Department of Respiratory Medicine, Imperial College Healthcare NHS Trust, London, UK.
- Imaging Department, Imperial College Healthcare NHS Trust, London, UK. a.alsafi@imperial.ac.uk.
- Department of Surgery and Cancer, Imperial College London, London, UK. a.alsafi@imperial.ac.uk.
Förderung
- Infrastructure support for this research was provided by the NIHR Imperial Biomedical Research Centre (BRC).
Zitieren
APA
Sheehan, F., Graham, A., Tait, N. P., Ind, P., Alsafi, A., & Jackson, J. E. (2024). Bronchial artery embolization using small particles is safe and effective: a single center 12-year experience. European Radiology, 34(12), 7786-7794. https://doi.org/10.1007/s00330-024-10836-y
Vancouver
Sheehan F, Graham A, Tait NP, Ind P, Alsafi A, Jackson JE. Bronchial artery embolization using small particles is safe and effective: a single center 12-year experience. European Radiology. 2024;34(12):7786-7794. doi:10.1007/s00330-024-10836-y
BibTeX
@article{Sheehan2024,
author = {Sheehan, Frances and Graham, Alison and Tait, N Paul and Ind, Philip and Alsafi, Ali and Jackson, James E},
title = {Bronchial artery embolization using small particles is safe and effective: a single center 12-year experience},
journal = {European Radiology},
year = {2024},
volume = {34},
number = {12},
pages = {7786--7794},
doi = {10.1007/s00330-024-10836-y}
}
EUVIMED