Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Nils Hendrix und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands. nils.hendrix@radboud…. Hauptthemen laut MEDLINE: Artificial Intelligence, Joint Instability. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To develop and validate an artificial intelligence (AI) system for measuring and detecting signs of carpal instability on conventional radiographs. Materials and methods Two case-control datasets of hand and wrist radiographs were retrospectively acquired at three hospitals (hospitals A, B, and C). Dataset 1 (2178 radiographs from 1993 patients, hospitals A and B, 2018–2019) was used for developing an AI system for measuring scapholunate (SL) joint distances, SL and capitolunate (CL) angles, and carpal arc interruptions. Dataset 2 (481 radiographs from 217 patients, hospital C, 2017–2021) was used for testing, and with a subsample (174 radiographs from 87 patients), an observer study was conducted to compare its performance to five clinicians. Evaluation metrics included mean absolute error (MAE), sensitivity, and specificity.

Results

Dataset 2 included 258 SL distances, 189 SL angles, 191 CL angles, and 217 carpal arc labels obtained from 217 patients (mean age, 51 years ± 23 [standard deviation]; 133 women). The MAE in measuring SL distances, SL angles, and CL angles was respectively 0.65 mm (95%CI: 0.59, 0.72), 7.9 degrees (95%CI: 7.0, 8.9), and 5.9 degrees (95%CI: 5.2, 6.6). The sensitivity and specificity for detecting arc interruptions were 83% (95%CI: 74, 91) and 64% (95%CI: 56, 71). The measurements were largely comparable to those of the clinicians, while arc interruption detections were more accurate than those of most clinicians.

Conclusion

This study demonstrates that a newly developed automated AI system accurately measures and detects signs of carpal instability on conventional radiographs. Clinical relevance statement This system has the potential to improve detections of carpal arc interruptions and could be a promising tool for supporting clinicians in detecting carpal instability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceJoint InstabilityHumansFemaleMiddle AgedMaleRetrospective StudiesSensitivity and SpecificityCase-Control StudiesAdultCarpal BonesRadiographyWrist JointCarpal JointsAged

Stichwörter der Autor:innen

Artificial intelligenceRadiographyWrist

Autor:innen und Institutionen

  • Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands. nils.hendrix@radboudumc.nl.
  • Jheronimus Academy of Data Science, Sint Janssingel 92, 5211 DA, 's-Hertogenbosch, The Netherlands. nils.hendrix@radboudumc.nl.
  • Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands.
  • Department of Radiology, Jeroen Bosch Ziekenhuis, Henri Dunantstraat 1, 5223 GZ, 's-Hertogenbosch, The Netherlands.
  • Department of Radiology, Ziekenhuis Gelderse Vallei, Willy Brandtlaan 10, 6717 RP, Ede, The Netherlands.
  • Department of Surgery, Ziekenhuis Gelderse Vallei, Willy Brandtlaan 10, 6717 RP, Ede, The Netherlands.

Zitieren

APA

Hendrix, N., Hendrix, W., Maresch, B., van Amersfoort, J., Oosterveld-Bonsma, T., Kolderman, S., Vestering, M., Zielinski, S., Rutten, K., Dammeier, J., Ong, L. S., van Ginneken, B., & Rutten, M. (2024). Artificial intelligence for automated detection and measurements of carpal instability signs on conventional radiographs. European Radiology. https://doi.org/10.1007/s00330-024-10744-1

Vancouver

Hendrix N, Hendrix W, Maresch B, van Amersfoort J, Oosterveld-Bonsma T, Kolderman S, et al. Artificial intelligence for automated detection and measurements of carpal instability signs on conventional radiographs. European Radiology. 2024. doi:10.1007/s00330-024-10744-1

BibTeX
@article{Hendrix2024,
  author = {Hendrix, Nils and Hendrix, Ward and Maresch, Bas and van Amersfoort, Job and Oosterveld-Bonsma, Tineke and Kolderman, Stephanie and Vestering, Myrthe and Zielinski, Stephanie and Rutten, Karlijn and Dammeier, Jan and Ong, Lee-Ling Sharon and van Ginneken, Bram and Rutten, Matthieu},
  title = {Artificial intelligence for automated detection and measurements of carpal instability signs on conventional radiographs},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10744-1}
}
Kostenlos starten →