EUVIMEDEUVIMED entdecken
Crossref

Reproducibility of artificial intelligence–enabled plaque measurements between systolic and diastolic phases from coronary computed tomography angiography

Guadalupe Flores Tomasino, Donghee Han, Raymond Pimentel, William Paz, Juni Liang, Victor Y Cheng, Piotr Slomka, Daniel S Berman, Damini Dey

European Radiology · 11.03.2024 · 34 (9) · 5705-5712

DOI: 10.1007/s00330-024-10688-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, online erschienen am 11.03.2024. Verfasst von Guadalupe Flores Tomasino und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Imaging and Medicine, and the, Cedars-Sinai Medical Center , Smidt Heart Institute, Los Angeles, CA, USA. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Artificial Intelligence, Plaque, Atherosclerotic, Coronary Angiography. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: NHLBI Division of Intramural Research, Dr. Miriam and Sheldon G. Adelson Medical Research Foundation, Winnick Family Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Current coronary CT angiography (CTA) guidelines suggest both end-systolic and mid-diastolic phases of the cardiac cycle can be used for CTA image acquisition. However, whether differences in the phase of the cardiac cycle influence coronary plaque measurements is not known. We aim to explore the potential impact of cardiac phases on quantitative plaque assessment. METHODS: We enrolled 39 consecutive patients (23 male, age 66.2 ± 11.5 years) who underwent CTA with dual-source CT with visually evident coronary atherosclerosis and with good image quality. End-systolic and mid- to late-diastolic phase images were reconstructed from the same CTA scan. Quantitative plaque and stenosis were analyzed in both systolic and diastolic images using artificial intelligence (AI)-enabled plaque analysis software (Autoplaque). RESULTS: Overall, 186 lesions from 39 patients were analyzed. There were excellent agreement and correlation between systolic and diastolic images for all plaque volume measurements (Lin's concordance coefficient ranging from 0.97 to 0.99; R ranging from 0.96 to 0.98). There were no substantial intrascan differences per patient between systolic and diastolic phases (p > 0.05 for all) for total (1017.1 ± 712.9 mm3 vs. 1014.7 ± 696.2 mm3), non-calcified (861.5 ± 553.7 mm3 vs. 856.5 ± 528.7 mm3), calcified (155.7 ± 229.3 mm3 vs. 158.2 ± 232.4 mm3), and low-density non-calcified plaque volume (151.4 ± 106.1 mm3 vs. 151.5 ± 101.5 mm3) and diameter stenosis (42.5 ± 18.4% vs 41.3 ± 15.1%). CONCLUSION: Excellent agreement and no substantial differences were observed in AI-enabled quantitative plaque measurements on CTA in systolic and diastolic images. Following further validation, standardized plaque measurements can be performed from CTA in systolic or diastolic cardiac phase. CLINICAL RELEVANCE STATEMENT: Quantitative plaque assessment using artificial intelligence-enabled plaque analysis software can provide standardized plaque quantification, regardless of cardiac phase. KEY POINTS: • The impact of different cardiac phases on coronary plaque measurements is unknown. • Plaque analysis using artificial intelligence-enabled software on systolic and diastolic CT angiography images shows excellent agreement. • Quantitative coronary artery plaque assessment can be performed regardless of cardiac phase.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyArtificial IntelligencePlaque, AtheroscleroticCoronary AngiographyCoronary Artery DiseaseSystoleDiastoleHumansMaleFemaleAgedReproducibility of ResultsMiddle AgedRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

AtherosclerosisAtherosclerotic plaqueComputed tomography angiographyCoronary artery disease

Autor:innen und Institutionen

  • Departments of Imaging and Medicine, and the, Cedars-Sinai Medical Center , Smidt Heart Institute, Los Angeles, CA, USA.
  • Minneapolis Heart Institute, Minneapolis, MN, USA.
  • Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, USA.
  • Cedars-Sinai Medical Center, Biomedical Imaging Research Institute, 116 N Robertson Blvd, Los Angeles, CA, 90048, USA. Damini.Dey@cshs.org.

Förderung

  • NHLBI Division of Intramural Research
  • Dr. Miriam and Sheldon G. Adelson Medical Research Foundation
  • Winnick Family Foundation

Zitieren

APA

Flores Tomasino, G., Han, D., Pimentel, R., Paz, W., Liang, J., Cheng, V. Y., Slomka, P., Berman, D. S., & Dey, D. (2024). Reproducibility of artificial intelligence–enabled plaque measurements between systolic and diastolic phases from coronary computed tomography angiography. European Radiology, 34(9), 5705-5712. https://doi.org/10.1007/s00330-024-10688-6

Vancouver

Flores Tomasino G, Han D, Pimentel R, Paz W, Liang J, Cheng VY, et al. Reproducibility of artificial intelligence–enabled plaque measurements between systolic and diastolic phases from coronary computed tomography angiography. European Radiology. 2024;34(9):5705-5712. doi:10.1007/s00330-024-10688-6

BibTeX
@article{FloresTomasino2024,
  author = {Flores Tomasino, Guadalupe and Han, Donghee and Pimentel, Raymond and Paz, William and Liang, Juni and Cheng, Victor Y and Slomka, Piotr and Berman, Daniel S and Dey, Damini},
  title = {Reproducibility of artificial intelligence–enabled plaque measurements between systolic and diastolic phases from coronary computed tomography angiography},
  journal = {European Radiology},
  year = {2024},
  volume = {34},
  number = {9},
  pages = {5705--5712},
  doi = {10.1007/s00330-024-10688-6}
}
Kostenlos starten →