Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound
European Radiology · 2024
DOI: 10.1007/s00330-024-10655-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Marie Byenfeldt und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology in Östersund, Östersund, Sweden. marie.byenfeldt@umu.se. Hauptthemen laut MEDLINE: Ultrasonography. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Research Foundation in Northern Sweden, Forskningsrådet i Sydöstra Sverige, Region Jämtland Härjedalen.
Abstract (Originalsprache)
Objectives
To evaluate the diagnostic performance of ultrasound guided attenuation parameter (UGAP) for evaluating liver fat content with different probe forces and body positions, in relation to sex, and compared with proton density fat fraction (PDFF).
Methods
We prospectively enrolled a metabolic dysfunction-associated steatotic liver disease (MASLD) cohort that underwent UGAP and PDFF in the autumn of 2022. Mean UGAP values were obtained in supine and 30° left decubitus body position with normal 4 N and increased 30 N probe force. The diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUC).
Results
Among 60 individuals (mean age 52.9 years, SD 12.9; 30 men), we found the best diagnostic performance with increased probe force in 30° left decubitus position (AUC 0.90; 95% CI 0.82–0.98) with a cut-off of 0.58 dB/cm/MHz. For men, the best performance was in supine (AUC 0.91; 95% CI 0.81–1.00) with a cut-off of 0.60 dB/cm/MHz, and for women, 30° left decubitus position (AUC 0.93; 95% CI 0.83–1.00), with a cut-off 0.56 dB/cm/MHz, and increased 30 N probe force for both genders. No difference was in the mean UGAP value when altering body position. UGAP showed good to excellent intra-reproducibility (Intra-class correlation 0.872; 95% CI 0.794–0.921).
Conclusion
UGAP provides excellent diagnostic performance to detect liver fat content in metabolic dysfunction-associated steatotic liver diseases, with good to excellent intra-reproducibility. Regardless of sex, the highest diagnostic accuracy is achieved with increased probe force with men in supine and women in 30° left decubitus position, yielding different cut-offs. Clinical relevance statement The ultrasound method ultrasound-guided attenuation parameter shows excellent diagnostic accuracy and performs with good to excellent reproducibility. There is a possibility to alter body position and increase probe pressure, and different performances for men and women should be considered for the highest accuracy. Key Points • There is a possibility to alter body position when performing the ultrasound method ultrasound-guided attenuation parameter. • Increase probe pressure for the highest accuracy. • Different performances for men and women should be considered. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology in Östersund, Östersund, Sweden. marie.byenfeldt@umu.se.
- Department of Radiation Science, Umeå University, Umeå, Sweden. marie.byenfeldt@umu.se.
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden. marie.byenfeldt@umu.se.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden. marie.byenfeldt@umu.se.
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
- Center for Medical Image Science and Visualization, Linköping University, Linköping, Sweden.
Förderung
- Cancer Research Foundation in Northern Sweden
- Forskningsrådet i Sydöstra Sverige
- Region Jämtland Härjedalen
- Linköping University
Zitieren
APA
Byenfeldt, M., Kihlberg, J., Nasr, P., Grönlund, C., Lindam, A., Bartholomä, W. C., Lundberg, P., & Ekstedt, M. (2024). Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound. European Radiology. https://doi.org/10.1007/s00330-024-10655-1
Vancouver
Byenfeldt M, Kihlberg J, Nasr P, Grönlund C, Lindam A, Bartholomä WC, et al. Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound. European Radiology. 2024. doi:10.1007/s00330-024-10655-1
BibTeX
@article{Byenfeldt2024,
author = {Byenfeldt, Marie and Kihlberg, Johan and Nasr, Patrik and Grönlund, Christer and Lindam, Anna and Bartholomä, Wolf C and Lundberg, Peter and Ekstedt, Mattias},
title = {Altered probe pressure and body position increase diagnostic accuracy for men and women in detecting hepatic steatosis using quantitative ultrasound},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-10655-1}
}
EUVIMED