EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of machine learning–based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease

Weifeng Guo, Shihai Zhao, Haijia Xu, Wei He, Lekang Yin, Zhifeng Yao, Zhihan Xu, Hang Jin, Dong Wu, Chenguang Li, Shan Yang, Mengsu Zeng

European Radiology · 2024

DOI: 10.1007/s00330-024-10650-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Radiology, 2024. Verfasst von Weifeng Guo und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China. Hauptthemen laut MEDLINE: Fractional Flow Reserve, Myocardial, Machine Learning, Coronary Artery Disease. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Shanghai Municipal Key Clinical Specialty.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis. METHODS: Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference. RESULTS: The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01). CONCLUSION: ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis. CLINICAL RELEVANCE STATEMENT: ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other. KEY POINTS: • Both machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and quantitative perfusion cardiac MR performed well in the detection of hemodynamically significant stenosis. • Compared with stress myocardial blood flow (MBF) from quantitative perfusion cardiac MR, myocardial perfusion reserve (MPR) provided higher diagnostic performance for detecting hemodynamically significant coronary artery stenosis. • ML-based CT-FFR and MPR from quantitative cardiac MR perfusion yielded similar diagnostic performance in assessing vessel-specific hemodynamically significant stenosis, whereas MPR had a favorable performance in per-patient analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractional Flow Reserve, MyocardialMachine LearningCoronary Artery DiseaseHumansMaleFemaleMiddle AgedProspective StudiesMagnetic Resonance ImagingCoronary AngiographyCoronary StenosisAgedComputed Tomography AngiographyMyocardial Perfusion ImagingTomography, X-Ray Computed

Stichwörter der Autor:innen

Coronary angiographyCoronary artery diseaseFractional flow reserve (myocardial)Multidetector computed tomographyMyocardial perfusion imaging

Autor:innen und Institutionen

  • Department of Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, Shanghai, 200032, China.
  • Department of Radiology, Shanghai Geriatric Medical Center, 2560 Chunshen Road, Minhang District, Shanghai, 201104, China.
  • Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • School of Basic Medical Sciences, Fudan University, Shanghai, 200032, China.
  • Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
  • Siemens Healthineers China, Shanghai, China.

Förderung

  • Shanghai Municipal Key Clinical Specialty

Zitieren

APA

Guo, W., Zhao, S., Xu, H., He, W., Yin, L., Yao, Z., Xu, Z., Jin, H., Wu, D., Li, C., Yang, S., & Zeng, M. (2024). Comparison of machine learning–based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease. European Radiology. https://doi.org/10.1007/s00330-024-10650-6

Vancouver

Guo W, Zhao S, Xu H, He W, Yin L, Yao Z, et al. Comparison of machine learning–based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease. European Radiology. 2024. doi:10.1007/s00330-024-10650-6

BibTeX
@article{Guo2024,
  author = {Guo, Weifeng and Zhao, Shihai and Xu, Haijia and He, Wei and Yin, Lekang and Yao, Zhifeng and Xu, Zhihan and Jin, Hang and Wu, Dong and Li, Chenguang and Yang, Shan and Zeng, Mengsu},
  title = {Comparison of machine learning–based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease},
  journal = {European Radiology},
  year = {2024},
  doi = {10.1007/s00330-024-10650-6}
}
Kostenlos starten →