Ablative margin quantification using deformable versus rigid image registration in colorectal liver metastasis thermal ablation: a retrospective single-center study
European Radiology · 2024
DOI: 10.1007/s00330-024-10632-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, 2024. Verfasst von Yuan-Mao Lin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX, 77030, USA. Hauptthemen laut MEDLINE: Liver Neoplasms, Colorectal Neoplasms, Tomography, X-Ray Computed. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NCI NIH HHS, Foundation for the National Institutes of Health.
Abstract (Originalsprache)
PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX, 77030, USA.
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX, 77030, USA.
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd, Houston, TX, 77030, USA. bcodisio@mdanderson.org.
Förderung
- NIH HHS
- NCI NIH HHS
- Foundation for the National Institutes of Health
- Postdoc.Mobility Fellowship from the Swiss National Science Foundation
- National Institutes of Health
Zitieren
APA
Lin, Y. M., Paolucci, I., Albuquerque Marques Silva, J., O'Connor, C. S., Hong, J., Shah, K. Y., Abdelsalam, M. E., Habibollahi, P., Jones, K. A., Brock, K. K., & Odisio, B. C. (2024). Ablative margin quantification using deformable versus rigid image registration in colorectal liver metastasis thermal ablation: a retrospective single-center study. European Radiology. https://doi.org/10.1007/s00330-024-10632-8
Vancouver
Lin YM, Paolucci I, Albuquerque Marques Silva J, O'Connor CS, Hong J, Shah KY, et al. Ablative margin quantification using deformable versus rigid image registration in colorectal liver metastasis thermal ablation: a retrospective single-center study. European Radiology. 2024. doi:10.1007/s00330-024-10632-8
BibTeX
@article{Lin2024,
author = {Lin, Yuan-Mao and Paolucci, Iwan and Albuquerque Marques Silva, Jessica and O'Connor, Caleb S and Hong, Jun and Shah, Ketan Y and Abdelsalam, Mohamed E and Habibollahi, Peiman and Jones, Kyle A and Brock, Kristy K and Odisio, Bruno C},
title = {Ablative margin quantification using deformable versus rigid image registration in colorectal liver metastasis thermal ablation: a retrospective single-center study},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-10632-8}
}
EUVIMED