Development and validation of AI-based automatic measurement of coronal Cobb angles in degenerative scoliosis using sagittal lumbar MRI
European Radiology · 21.02.2024 · 34 (9) · 5748-5757
DOI: 10.1007/s00330-024-10616-8 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift European Radiology, online erschienen am 21.02.2024. Verfasst von Jasper W van der Graaf und 7 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic Image Analysis Group, Radboud University Medical Center Nijmegen, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands. jasper.vandergraaf@gm…. Hauptthemen laut MEDLINE: Scoliosis, Magnetic Resonance Imaging, Lumbar Vertebrae, Algorithms. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Radboud AI for Health.
Abstract (Originalsprache)
Objectives
Severity of degenerative scoliosis (DS) is assessed by measuring the Cobb angle on anteroposterior radiographs. However, MRI images are often available to study the degenerative spine. This retrospective study aims to develop and evaluate the reliability of a novel automatic method that measures coronal Cobb angles on lumbar MRI in DS patients. Materials and methods Vertebrae and intervertebral discs were automatically segmented using a 3D AI algorithm, trained on 447 lumbar MRI series. The segmentations were used to calculate all possible angles between the vertebral endplates, with the largest being the Cobb angle. The results were validated with 50 high-resolution sagittal lumbar MRI scans of DS patients, in which three experienced readers measured the Cobb angle. Reliability was determined using the intraclass correlation coefficient (ICC).
Results
The ICCs between the readers ranged from 0.90 (95% CI 0.83–0.94) to 0.93 (95% CI 0.88–0.96). The ICC between the maximum angle found by the algorithm and the average manually measured Cobb angles was 0.83 (95% CI 0.71–0.90). In 9 out of the 50 cases (18%), all readers agreed on both vertebral levels for Cobb angle measurement. When using the algorithm to extract the angles at the vertebral levels chosen by the readers, the ICCs ranged from 0.92 (95% CI 0.87–0.96) to 0.97 (95% CI 0.94–0.98).
Conclusion
The Cobb angle can be accurately measured on MRI using the newly developed algorithm in patients with DS. The readers failed to consistently choose the same vertebral level for Cobb angle measurement, whereas the automatic approach ensures the maximum angle is consistently measured. Clinical relevance statement Our AI-based algorithm offers reliable Cobb angle measurement on routine MRI for degenerative scoliosis patients, potentially reducing the reliance on conventional radiographs, ensuring consistent assessments, and therefore improving patient care. Key Points • While often available, MRI images are rarely utilized to determine the severity of degenerative scoliosis. • The presented MRI Cobb angle algorithm is more reliable than humans in patients with degenerative scoliosis. • Radiographic imaging for Cobb angle measurements is mitigated when lumbar MRI images are available. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Diagnostic Image Analysis Group, Radboud University Medical Center Nijmegen, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands. jasper.vandergraaf@gmail.com.
- Department of Orthopedics, Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands. jasper.vandergraaf@gmail.com.
- Department of Orthopedics, Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands.
- Department of Research, Sint Maartenskliniek, Nijmegen, The Netherlands.
- Diagnostic Image Analysis Group, Radboud University Medical Center Nijmegen, P.O. Box 9101, Nijmegen, 6500 HB, The Netherlands.
- Department of Medical Imaging, Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands.
Förderung
- Radboud AI for Health
Zitieren
APA
van der Graaf, J. W., van Hooff, M. L., van Ginneken, B., Huisman, M., Rutten, M., Lamers, D., Lessmann, N., & de Kleuver, M. (2024). Development and validation of AI-based automatic measurement of coronal Cobb angles in degenerative scoliosis using sagittal lumbar MRI. European Radiology, 34(9), 5748-5757. https://doi.org/10.1007/s00330-024-10616-8
Vancouver
van der Graaf JW, van Hooff ML, van Ginneken B, Huisman M, Rutten M, Lamers D, et al. Development and validation of AI-based automatic measurement of coronal Cobb angles in degenerative scoliosis using sagittal lumbar MRI. European Radiology. 2024;34(9):5748-5757. doi:10.1007/s00330-024-10616-8
BibTeX
@article{vanderGraaf2024,
author = {van der Graaf, Jasper W and van Hooff, Miranda L and van Ginneken, Bram and Huisman, Merel and Rutten, Matthieu and Lamers, Dominique and Lessmann, Nikolas and de Kleuver, Marinus},
title = {Development and validation of AI-based automatic measurement of coronal Cobb angles in degenerative scoliosis using sagittal lumbar MRI},
journal = {European Radiology},
year = {2024},
volume = {34},
number = {9},
pages = {5748--5757},
doi = {10.1007/s00330-024-10616-8}
}
EUVIMED