EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the optimal MRI descriptors to diagnose Ménière’s disease and the added value of analysing the vestibular aqueduct

Steve Connor, Irumee Pai, Philip Touska, Sarah McElroy, Sebastien Ourselin, Joseph V Hajnal

European Radiology · 07.02.2024 · 34 (9) · 6060-6071

DOI: 10.1007/s00330-024-10587-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, online erschienen am 07.02.2024. Verfasst von Steve Connor und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK. steve.connor@kcl.ac.uk. Hauptthemen laut MEDLINE: Meniere Disease, Magnetic Resonance Imaging, Vestibular Aqueduct. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Research UK, Wellcome Trust, NIHR Biomedical Research Centre Guy's and St Thomas' Hospital and King's College London.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the diagnostic performance and reliability of MRI descriptors used for the detection of Ménière’s disease (MD) on delayed post-gadolinium MRI. To determine which combination of descriptors should be optimally applied and whether analysis of the vestibular aqueduct (VA) contributes to the diagnosis. Materials and methods This retrospective single centre case-control study evaluated delayed post-gadolinium MRI of patients with Ménièriform symptoms examined consecutively between Dec 2017 and March 2023. Two observers evaluated 17 MRI descriptors of MD and quantified perilymphatic enhancement (PLE) in the cochlea. Definite MD ears according to the 2015 Barany Society criteria were compared to control ears. Cohen’s kappa and diagnostic odds ratio (DORs) were calculated for each descriptor. Forward stepwise logistic regression determined which combination of MRI descriptors would best predict MD ears, and the area under the receiver operating characteristic curve for this model was measured.

Results

A total of 227 patients (mean age 48.3 ± 14.6, 99 men) with 96 definite MD and 78 control ears were evaluated. The presence of saccular abnormality (absent, as large as or confluent with the utricle) performed best with a DOR of 292.6 (95% confidence interval (CI), 38.305–2235.058). All VA descriptors demonstrated excellent reliability and with DORs of 7.761 (95% CI, 3.517–17.125) to 18.1 (95% CI, 8.445–39.170). Combining these saccular abnormalities with asymmetric cochlear PLE and an incompletely visualised VA correctly classified 90.2% of cases (sensitivity 84.4%, specificity 97.4%, AUC 0.938).

Conclusion

Either absent, enlarged or confluent saccules are the best predictors of MD. Incomplete visualisation of the VA adds value to the diagnosis. Clinical relevance statement A number of different MRI descriptors have been proposed for the diagnosis of Ménière’s disease, but by establishing the optimally performing MRI features and highlighting new useful descriptors, there is an opportunity to improve the diagnostic performance of Ménière’s disease imaging. Key Points • A comprehensive range of existing and novel vestibular aqueduct delayed post-gadolinium MRI descriptors were compared for their diagnostic performance in Ménière’s disease. • Saccular abnormality (absent, confluent with or larger than the utricle) is a reliable descriptor and is the optimal individual MRI predictor of Ménière’s disease. • The presence of this saccule descriptor or asymmetric perilymphatic enhancement and incomplete vestibular aqueduct visualisation will optimise the MRI diagnosis of Ménière’s disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Meniere DiseaseMagnetic Resonance ImagingVestibular AqueductHumansMaleFemaleMiddle AgedRetrospective StudiesCase-Control StudiesReproducibility of ResultsAdultGadoliniumSensitivity and SpecificityContrast Media

Stichwörter der Autor:innen

Endolymphatic hydropsInner earMagnetic resonance imagingOdds ratioVestibular aqueduct

Substanzen

GadoliniumContrast Media

Autor:innen und Institutionen

  • School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK. steve.connor@kcl.ac.uk.
  • Department of Neuroradiology, King's College Hospital, London, SE5 9RS, UK. steve.connor@kcl.ac.uk.
  • Department of Radiology, Guy's Hospital and St Thomas' Hospital, London, SE1 9RT, UK. steve.connor@kcl.ac.uk.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, St Thomas' Hospital, London, SE1 7EH, UK.
  • Department of Ear, Nose and Throat Surgery, Guy's and St Thomas' Hospital, London, SE1 9RT, UK.
  • Department of Radiology, Guy's Hospital and St Thomas' Hospital, London, SE1 9RT, UK.

Förderung

  • Cancer Research UK
  • Wellcome Trust
  • NIHR Biomedical Research Centre Guy's and St Thomas' Hospital and King's College London
  • UK Research and Innovation London Medical Imaging and Artificial Intelligence Centre

Zitieren

APA

Connor, S., Pai, I., Touska, P., McElroy, S., Ourselin, S., & Hajnal, J. V. (2024). Assessing the optimal MRI descriptors to diagnose Ménière’s disease and the added value of analysing the vestibular aqueduct. European Radiology, 34(9), 6060-6071. https://doi.org/10.1007/s00330-024-10587-w

Vancouver

Connor S, Pai I, Touska P, McElroy S, Ourselin S, Hajnal JV. Assessing the optimal MRI descriptors to diagnose Ménière’s disease and the added value of analysing the vestibular aqueduct. European Radiology. 2024;34(9):6060-6071. doi:10.1007/s00330-024-10587-w

BibTeX
@article{Connor2024,
  author = {Connor, Steve and Pai, Irumee and Touska, Philip and McElroy, Sarah and Ourselin, Sebastien and Hajnal, Joseph V},
  title = {Assessing the optimal MRI descriptors to diagnose Ménière’s disease and the added value of analysing the vestibular aqueduct},
  journal = {European Radiology},
  year = {2024},
  volume = {34},
  number = {9},
  pages = {6060--6071},
  doi = {10.1007/s00330-024-10587-w}
}
Kostenlos starten →