EUVIMEDEUVIMED entdecken
Multizentrische Studie

Analysis of Sonazoid contrast-enhanced ultrasound for predicting the risk of microvascular invasion in hepatocellular carcinoma: a prospective multicenter study

Jundong Yao, Kaiyan Li, Hong Yang, Shichun Lu, Hong Ding, Yan Luo, Kai Li, Xiaoyan Xie, Wei Wu, Xiang Jing, Fangyi Liu, Jie Yu und 11 weitere

European Radiology · 28.04.2023 · 33 (10) · 7066-7076

DOI: 10.1007/s00330-023-09656-3 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Radiology, online erschienen am 28.04.2023. Verfasst von Jundong Yao und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Ultrasound, First Medical Center of Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China. Hauptthemen laut MEDLINE: Carcinoma, Hepatocellular, Liver Neoplasms. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: The aim of this study was to evaluate the potential of Sonazoid contrast-enhanced ultrasound (SNZ-CEUS) as an imaging biomarker for preoperative prediction of microvascular invasion (MVI) in hepatocellular carcinoma (HCC). METHODS: From August 2020 to March 2021, we conducted a prospective multicenter study on the clinical application of Sonazoid in liver tumor; a MVI prediction model was developed and validated by integrating clinical and imaging variables. Multivariate logistic regression analysis was used to establish the MVI prediction model; three models were developed: a clinical model, a SNZ-CEUS model, and a combined model and conduct external validation. We conducted subgroup analysis to investigate the performance of the SNZ-CEUS model in non-invasive prediction of MVI. RESULTS: Overall, 211 patients were evaluated. All patients were split into derivation (n = 170) and external validation (n = 41) cohorts. Patients who had MVI accounted for 89 of 211 (42.2%) patients. Multivariate analysis revealed that tumor size (> 49.2 mm), pathology differentiation, arterial phase heterogeneous enhancement pattern, non-single nodular gross morphology, washout time (< 90 s), and gray value ratio (≤ 0.50) were significantly associated with MVI. Combining these factors, the area under the receiver operating characteristic (AUROC) of the combined model in the derivation and external validation cohorts was 0.859 (95% confidence interval (CI): 0.803-0.914) and 0.812 (95% CI: 0.691-0.915), respectively. In subgroup analysis, the AUROC of the SNZ-CEUS model in diameter ≤ 30 mm and ˃ 30 mm cohorts were 0.819 (95% CI: 0.698-0.941) and 0.747 (95% CI: 0.670-0.824). CONCLUSIONS: Our model predicted the risk of MVI in HCC patients with high accuracy preoperatively. CLINICAL RELEVANCE STATEMENT: Sonazoid, a novel second-generation ultrasound contrast agent, can accumulate in the endothelial network and form a unique Kupffer phase in liver imaging. The preoperative non-invasive prediction model based on Sonazoid for MVI is helpful for clinicians to make individualized treatment decisions. KEY POINTS: • This is the first prospective multicenter study to analyze the possibility of SNZ-CEUS preoperatively predicting MVI. • The model established by combining SNZ-CEUS image features and clinical features has high predictive performance in both derivation cohort and external validation cohort. • The findings can help clinicians predict MVI in HCC patients before surgery and provide a basis for optimizing surgical management and monitoring strategies for HCC patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carcinoma, HepatocellularLiver NeoplasmsHumansProspective StudiesRetrospective StudiesNeoplasm InvasivenessRisk FactorsFerric CompoundsIronOxides

Stichwörter der Autor:innen

Diagnostic imagingLiver neoplasmsSonazoid

Substanzen

SonazoidFerric CompoundsIronOxides

Autor:innen und Institutionen

  • Department of Interventional Ultrasound, First Medical Center of Chinese PLA General Hospital, No. 28 Fuxing Road, Beijing, 100853, China.
  • Chinese PLA Medical School, Beijing, 100853, China.
  • Department of Ultrasound Imaging, Affiliated Tongji Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
  • Department of Ultrasound, the First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China.
  • Department of Hepatobiliary Surgery, First Medical Center of Chinese PLA General Hospital, Beijing, 100853, China.
  • Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, 200040, China.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Yao, J., Li, K., Yang, H., Lu, S., Ding, H., Luo, Y., Li, K., Xie, X., Wu, W., Jing, X., Liu, F., Yu, J., Cheng, Z., Tan, S., Dou, J., Dong, X., Wang, S., Zhang, Y., Li, Y., …, & Yu, X. (2023). Analysis of Sonazoid contrast-enhanced ultrasound for predicting the risk of microvascular invasion in hepatocellular carcinoma: a prospective multicenter study. European Radiology, 33(10), 7066-7076. https://doi.org/10.1007/s00330-023-09656-3

Vancouver

Yao J, Li K, Yang H, Lu S, Ding H, Luo Y, et al. Analysis of Sonazoid contrast-enhanced ultrasound for predicting the risk of microvascular invasion in hepatocellular carcinoma: a prospective multicenter study. European Radiology. 2023;33(10):7066-7076. doi:10.1007/s00330-023-09656-3

BibTeX
@article{Yao2023,
  author = {Yao, Jundong and Li, Kaiyan and Yang, Hong and Lu, Shichun and Ding, Hong and Luo, Yan and Li, Kai and Xie, Xiaoyan and Wu, Wei and Jing, Xiang and Liu, Fangyi and Yu, Jie and Cheng, Zhigang and Tan, Shuilian and Dou, Jianping and Dong, XueJuan and Wang, Shuo and Zhang, Yiqiong and Li, Yunlin and Qi, Erpeng and Han, Zhiyu and Liang, Ping and Yu, XiaoLing},
  title = {Analysis of Sonazoid contrast-enhanced ultrasound for predicting the risk of microvascular invasion in hepatocellular carcinoma: a prospective multicenter study},
  journal = {European Radiology},
  year = {2023},
  volume = {33},
  number = {10},
  pages = {7066--7076},
  doi = {10.1007/s00330-023-09656-3}
}
Kostenlos starten →