EUVIMEDEUVIMED entdecken
MetaanalyseSystematische Übersicht

Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures

Tae Yeon Jeon, Moon Hyung Choi, Seung Bae Yoon, Jae Seung Soh, Sung-Hoon Moon

European Radiology · 2022-03 · 32 (3) · 1747-1756

DOI: 10.1007/s00330-021-08301-1 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift European Radiology, online erschienen am 18.09.2021. Verfasst von Tae Yeon Jeon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Bile Duct Neoplasms, Cholestasis. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To perform a systematic review and meta-analysis to determine the diagnostic performance of percutaneous transluminal forceps biopsy (PTFB) for differentiating malignant from benign biliary stricture. METHODS: A comprehensive literature search of the PubMed, EMBASE, and Ovid MEDLINE databases was conducted to identify original articles published between January 2001 and January 2021 reporting the diagnostic accuracy of PTFB. A random-effects model was used to summarize the diagnostic odds ratio and other measures of accuracy. RESULTS: Fourteen studies involving 1762 patients met the inclusion criteria and were included in the meta-analysis. The meta-analysis summary estimates of PTFB for diagnosis of malignant biliary strictures were as follows: sensitivity 81% (95% confidence interval [CI], 78-81%); specificity 100% (95% CI, 98-100%); diagnostic odds ratio 85.34 (95% CI, 38.37-189.81). The area under the curve of PTFB was 0.948 in the diagnosis of malignant biliary strictures. The diagnostic sensitivity was higher in intrinsic (85%) than in extrinsic (73%) biliary strictures. The pooled rate of all complications was 10.3% (95% CI, 7.0-14.2%), including a major complication rate of 3.1%. CONCLUSION: These data demonstrate that PTFB is sensitive and highly specific for diagnosing malignancy in biliary strictures. PTFB should be incorporated into future guidelines for tissue sampling in biliary cancer, especially in cases with failed endoscopic management. KEY POINTS: • PTFB had a good overall diagnostic performance for differentiating malignant from benign biliary strictures, with a meta-analysis summary estimate of 81% for sensitivity and 100% for specificity. • PTFB had higher sensitivity for cholangiocarcinoma (85%) than for other cancers (73%). • PTFB had a 100% technical success rate and a 10.3% rate for complications, including a 3.1% rate for major complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bile Duct NeoplasmsCholestasisBile Ducts, IntrahepaticBiopsyCholangiopancreatography, Endoscopic RetrogradeConstriction, PathologicHumansSensitivity and SpecificitySurgical Instruments

Stichwörter der Autor:innen

Biliary tract neoplasmsBiopsyCholestasisInterventional radiography

Autor:innen und Institutionen

  • Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Department of Radiology, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
  • Department of Internal Medicine, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 06591, South Korea. sbyoon@catholic.ac.kr.
  • Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, 22, Gwanpyeong-ro 170 beon-gil, Dongan-gu, Anyang, Gyeonggi-do, 14068, South Korea.
  • Department of Internal Medicine, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, 22, Gwanpyeong-ro 170 beon-gil, Dongan-gu, Anyang, Gyeonggi-do, 14068, South Korea. endomoon@hallym.or.kr.

Zitieren

APA

Jeon, T. Y., Choi, M. H., Yoon, S. B., Soh, J. S., & Moon, S. H. (2022). Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures. European Radiology, 32(3), 1747-1756. https://doi.org/10.1007/s00330-021-08301-1

Vancouver

Jeon TY, Choi MH, Yoon SB, Soh JS, Moon SH. Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures. European Radiology. 2022;32(3):1747-1756. doi:10.1007/s00330-021-08301-1

BibTeX
@article{Jeon2022,
  author = {Jeon, Tae Yeon and Choi, Moon Hyung and Yoon, Seung Bae and Soh, Jae Seung and Moon, Sung-Hoon},
  title = {Systematic review and meta-analysis of percutaneous transluminal forceps biopsy for diagnosing malignant biliary strictures},
  journal = {European Radiology},
  year = {2022},
  volume = {32},
  number = {3},
  pages = {1747--1756},
  doi = {10.1007/s00330-021-08301-1}
}
Kostenlos starten →