Do plaque-related factors affect the diagnostic performance of an artificial intelligence coronary-assisted diagnosis system? Comparison with invasive coronary angiography

Jie Xu, Linli Chen, Xiaojia Wu, Chuanming Li, Guangyong Ai, Yuexi Liu, Bitong Tian, Dajing Guo, Zheng Fang

European Radiology · 2022-03 · 32 (3) · 1866-1878

DOI: 10.1007/s00330-021-08299-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, online erschienen am 26.09.2021. Verfasst von Jie Xu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. Hauptthemen laut MEDLINE: Coronary Artery Disease, Coronary Stenosis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: the Kuanren Talents Program of the Second Affiliated Hospital of Chongqing Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The aim of this study was to investigate the effects of plaque-related factors on the diagnostic performance of an artificial intelligence coronary-assisted diagnosis system (AI-CADS). METHODS: Patients who underwent coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) were retrospectively included in this study. The degree of stenosis in each vessel was collected from CCTA and ICA, and the information on plaque-related factors (plaque length, plaque type, and coronary artery calcium score (CAC)) of the vessels with plaques was collected from CCTA. RESULTS: In total, 1224 vessels in 306 patients (166 men; 65.7 ± 10.1 years) were analyzed. Of these, 391 vessels in 249 patients showed significant stenosis using ICA as the gold standard. Using per-vessel as the unit, the area under the curves of coronary stenosis ≥ 50% for AI-CADS, doctor, and AI-CADS + doctor was 0.764, 0.837, and 0.853, respectively. The accuracies in interpreting the degree of coronary stenosis were 56.0%, 68.1%, and 71.2%, respectively. Seven hundred fifty vessels showed plaques on CCTA; plaque type did not affect the interpretation results by AI-CADS (chi-square test: p = 0.0093; multiple logistic regression: p = 0.4937). However, the interpretation results for plaque length (chi-square test: p < 0.0001; multiple logistic regression: p = 0.0061) and CACs (chi-square test: p < 0.0001; multiple logistic regression: p = 0.0001) were significantly different. CONCLUSION: AI-CADS has an ability to distinguish ≥ 50% coronary stenosis, but additional manual interpretation based on AI-CADS is necessary. The plaque length and CACs will affect the diagnostic performance of AI-CADS. KEY POINTS: • AI-CADS can help radiologists quickly assess CCTA and improve diagnostic confidence. • Additional manual interpretation on the basis of AI-CADS is necessary. • The plaque length and CACs will affect the diagnostic performance of AI-CADS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery DiseaseCoronary StenosisArtificial IntelligenceComputed Tomography AngiographyCoronary AngiographyCoronary VesselsHumansMalePredictive Value of TestsRetrospective Studies

Stichwörter der Autor:innen

Artificial intelligenceComputed tomography angiographyCoronary stenosis

Autor:innen und Institutionen

  • Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China.
  • Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. guodaj@163.com.
  • Department of Radiology, the Second Affiliated Hospital of Chongqing Medical University, Chongqing, China. wwwfans2000@hospital.cqmu.edu.cn.

Förderung

  • the Kuanren Talents Program of the Second Affiliated Hospital of Chongqing Medical University

Zitieren

APA

Xu, J., Chen, L., Wu, X., Li, C., Ai, G., Liu, Y., Tian, B., Guo, D., & Fang, Z. (2022). Do plaque-related factors affect the diagnostic performance of an artificial intelligence coronary-assisted diagnosis system? Comparison with invasive coronary angiography. European Radiology, 32(3), 1866-1878. https://doi.org/10.1007/s00330-021-08299-6

Vancouver

Xu J, Chen L, Wu X, Li C, Ai G, Liu Y, et al. Do plaque-related factors affect the diagnostic performance of an artificial intelligence coronary-assisted diagnosis system? Comparison with invasive coronary angiography. European Radiology. 2022;32(3):1866-1878. doi:10.1007/s00330-021-08299-6

BibTeX
@article{Xu2022,
  author = {Xu, Jie and Chen, Linli and Wu, Xiaojia and Li, Chuanming and Ai, Guangyong and Liu, Yuexi and Tian, Bitong and Guo, Dajing and Fang, Zheng},
  title = {Do plaque-related factors affect the diagnostic performance of an artificial intelligence coronary-assisted diagnosis system? Comparison with invasive coronary angiography},
  journal = {European Radiology},
  year = {2022},
  volume = {32},
  number = {3},
  pages = {1866--1878},
  doi = {10.1007/s00330-021-08299-6}
}
Kostenlos starten →