Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery
Surgical and Radiologic Anatomy · 11.11.2026 · 48 (1)
DOI: 10.1007/s00276-026-04046-y ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Surgical and Radiologic Anatomy, online erschienen am 11.11.2026. Verfasst von Julia Szopa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Student Research Society, Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Pol…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Arteries. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Warszawski Uniwersytet Medyczny.
Abstract (Originalsprache)
Cadaveric dissection is a traditional method used to reveal deep-seated anatomical structures; however, it is inherently time-consuming and irreversible, preventing the correction of procedural errors. To address these limitations, this feasibility study proposes a novel computer-assisted, "digital dissection" framework designed to accelerate workflow, allow error mitigation, and enable repeatable analysis of a single specimen. Four independent observers performed "digital dissections" of the inferior medial genicular artery across two DICOM viewing platforms: RadiANT DICOM Viewer 2025.2 (64-bit) and Horos v4.0.0 RC5. Morphometric measurements were recorded at predefined reference points corresponding to arterial branching sites. Inter-observer variability was evaluated, and the resulting dataset was validated against multiplanar reconstruction (MPR) metrics-the standard radiological benchmark for vascular assessment. Statistical analysis revealed no significant difference between three-dimensional volume rendering (3D VR) and MPR in assessing vessel dimensions for structures with a diameter exceeding (dMPR=0.950 mm). For vessels > 0.95 mm, 3D-VR and MPR yielded no statistically significant difference (p = 0.086), a strong Pearson correlation (r = 0.971), and a Bland‑Altman mean bias of -0.03 mm (95% LoA: - 0.14 to +0.07 mm). Furthermore, morphological consistency was maintained regardless of vessel caliber. The integration of 3D VR and MPR modalities would offer a cost-effective, highly reproducible, non-invasive tool for both educational and research applications in vascular analysis. Moreover, these measurements exhibit strong stability across different software platforms and operators, showing an absence of systematic bias with only minor variations attributable to human error or minor misalignment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Student Research Society, Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Poland.
- Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Poland.
- Department of Radiology, MiraiClinic, Otwock, Poland.
- Department of Descriptive and Clinical Anatomy, Center for Biostructure Research, Medical University of Warsaw, Warsaw, Poland. robert.smigielski@interia.com.
- Department of Trauma, Orthopedics and Sports Medicine, Life Medical Center, Warsaw, Poland. robert.smigielski@interia.com.
Förderung
- Warszawski Uniwersytet Medyczny
Zitieren
APA
Szopa, J., Fortuna, L., Gębski, P., Lipiński, F., Ciszek, B., Ciszkowska-Łysoń, B., & Śmigielski, R. (2026). Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery. Surgical and Radiologic Anatomy, 48(1). https://doi.org/10.1007/s00276-026-04046-y
Vancouver
Szopa J, Fortuna L, Gębski P, Lipiński F, Ciszek B, Ciszkowska-Łysoń B, et al. Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery. Surgical and Radiologic Anatomy. 2026;48(1). doi:10.1007/s00276-026-04046-y
BibTeX
@article{Szopa2026,
author = {Szopa, Julia and Fortuna, Laura and Gębski, Paweł and Lipiński, Filip and Ciszek, Bogdan and Ciszkowska-Łysoń, Beata and Śmigielski, Robert},
title = {Multi-planar reconstruction and 3D volume rendering as tools of anatomical dissection and morphometry on the example of cadaveric study of inferior medial genicular artery},
journal = {Surgical and Radiologic Anatomy},
year = {2026},
volume = {48},
number = {1},
doi = {10.1007/s00276-026-04046-y}
}
EUVIMED