EUVIMEDEUVIMED entdecken
Vergleichsstudie

The comparison of biomechanical and histological findings of cadaveric temporal fascia and dura mater grafts

Onurhan Güven, Zeliha Kurtoğlu Olgunus, Orhan Beger, Rabia Bozdoğan Arpacı, Ülkü Çömelekoğlu, Gözde Arslan, Pourya Taghipour, Yusuf Vayısoğlu, Derya Ümit Talas

Surgical and Radiologic Anatomy · 14.07.2026 · 48 (1)

DOI: 10.1007/s00276-026-03935-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Surgical and Radiologic Anatomy, online erschienen am 14.07.2026. Verfasst von Onurhan Güven und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Islahiye State Hospital, Gaziantep, Turkey. onurhan.guven@gmail.com. Hauptthemen laut MEDLINE: Dura Mater, Fascia. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This research aims to analyze and compare the biomechanical and histological characteristics of temporal fascia (TF) and dura mater grafts (DM); both obtained from adult human cadavers preserved in 10% formalin solution. METHODS: TF and DM samples (bilateral, n = 3 strips per tissue) were obtained from 12 adult human cadavers (6 males, 6 females, age 46-86, mean 73) preserved in 10% formalin solution. Biomechanical tensile test was used to measure the maximum force, stiffness, energy absorption, and maximum deformation, maximum stress, maximum strain, elastic (Young's) modulus, and toughness. Histological analysis assessed collagen and elastic fiber densities using standard staining methods via Pentachrome, Masson Trichrome and Verhoeff staining. RESULTS: The elastic modulus, ultimate stress, and toughness were higher in formalin-fixed temporalis fascia than in formalin-fixed dura mater, indicating a stiffer material behavior. Histologically, collagen fiber and elastic fiber densities of grafts were similar. CONCLUSION: Formalin-fixed temporal fascia exhibited higher stiffness and tensile strength than formalin-fixed dura mater, likely due to fixation-induced structural alterations rather than differences in elastic fiber content.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dura MaterFasciaHumansFemaleAgedCadaverMiddle AgedAged, 80 and overMaleBiomechanical PhenomenaTensile StrengthCollagenFormaldehydeTissue Fixation

Stichwörter der Autor:innen

BiomechanicsCollagenDura materElasticityHistologyTemporal fascia

Substanzen

CollagenFormaldehyde

Autor:innen und Institutionen

  • Department of Otolaryngology, Islahiye State Hospital, Gaziantep, Turkey. onurhan.guven@gmail.com.
  • Faculty of Medicine, Department of Anatomy, Mersin University, Mersin, Turkey.
  • Faculty of Medicine, Department of Anatomy, Gaziantep University, Gaziantep, Turkey.
  • Faculty of Medicine, Department of Pathology, Mersin University, Mersin, Turkey.
  • Faculty of Medicine, Department of Biophysics, Mersin University, Mersin, Turkey.
  • Faculty of Medicine, Mersin University, Mersin, Turkey.

Zitieren

APA

Güven, O., Olgunus, Z. K., Beger, O., Arpacı, R. B., Çömelekoğlu, Ü., Arslan, G., Taghipour, P., Vayısoğlu, Y., & Talas, D. Ü. (2026). The comparison of biomechanical and histological findings of cadaveric temporal fascia and dura mater grafts. Surgical and Radiologic Anatomy, 48(1). https://doi.org/10.1007/s00276-026-03935-6

Vancouver

Güven O, Olgunus ZK, Beger O, Arpacı RB, Çömelekoğlu Ü, Arslan G, et al. The comparison of biomechanical and histological findings of cadaveric temporal fascia and dura mater grafts. Surgical and Radiologic Anatomy. 2026;48(1). doi:10.1007/s00276-026-03935-6

BibTeX
@article{Gven2026,
  author = {Güven, Onurhan and Olgunus, Zeliha Kurtoğlu and Beger, Orhan and Arpacı, Rabia Bozdoğan and Çömelekoğlu, Ülkü and Arslan, Gözde and Taghipour, Pourya and Vayısoğlu, Yusuf and Talas, Derya Ümit},
  title = {The comparison of biomechanical and histological findings of cadaveric temporal fascia and dura mater grafts},
  journal = {Surgical and Radiologic Anatomy},
  year = {2026},
  volume = {48},
  number = {1},
  doi = {10.1007/s00276-026-03935-6}
}
Kostenlos starten →