Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study
Surgical and Radiologic Anatomy · 2025
DOI: 10.1007/s00276-025-03599-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgical and Radiologic Anatomy, 2025. Verfasst von Derya Karatas und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Mersin University Faculty of Medicine, Mersin, Türkiye. k_derya@yahoo.com. Hauptthemen laut MEDLINE: Pedicle Screws, Vertebral Artery, Cervical Vertebrae, Anatomic Variation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Mersin University scientific research projects coordination unit.
Abstract (Originalsprache)
PURPOSE: The aim of the present study is to analyze the feasibility of a new optimized C1 lateral mass and C2 pedicle screw method that has a suitable trajectory for a range of anatomical variations to decrease the risk of vertebral artery injury. METHODS: The craniovertebral junction of 17 cadavers (34 sides) were dissected after performing thin-cut computed tomography. The screw entry points, targets, angles, and lengths of the trajectories were performed for C1 lateral mass and C2 pedicle. We particularly focused on the morphometric features and the safety of trajectories in cadavers with vascular and bony variations. RESULTS: For the C1 lateral mass, the ideal medial and cranial angles were 13.4° ± 1.0° and 14.7° ± 1.1°, respectively. For the C2 pedicle screw, the cranial and medial angles were 27.7° ± 1.4° and 20.4° ± 1.5°, respectively. High-riding vertebral arteries (HRVA) were observed in 35.3% of all cadavers. The incidence of an arcuate foramen was 47% among all sides and its coexistence with an HRVA among all cadavers was 23.5%. CONCLUSION: Preoperative pedicle-oriented radiological evaluation is crucial before C1 lateral mass and C2 pedicle screw placement because of the high incidence of bony and vascular variations. Using our safe C2 pedicle trajectory, a longer and safer screw course that preserves the vertebral artery can be achieved with a more feasible cranial angle, even with HRVAs, with the exception of narrow pedicle anatomy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurosurgery, Mersin University Faculty of Medicine, Mersin, Türkiye. k_derya@yahoo.com.
- Department of Neurosurgery, Mersin University Faculty of Medicine, Mersin, Türkiye.
- Department of Neurosurgery, Kadirli State Hospital, Osmaniye, Türkiye.
- Department of Radiology, Mersin University Faculty of Medicine, Mersin, Türkiye.
- Department of Neurosurgery, University of Wisconsin-Madison School of Medicine and Public Health, Madison, USA.
Förderung
- Mersin University scientific research projects coordination unit
Zitieren
APA
Karatas, D., Dagtekin, A., Uygur, S., Barut, I. T., Kara, E., Esen, K., Avci, E., & Baskaya, M. K. (2025). Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study. Surgical and Radiologic Anatomy. https://doi.org/10.1007/s00276-025-03599-8
Vancouver
Karatas D, Dagtekin A, Uygur S, Barut IT, Kara E, Esen K, et al. Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study. Surgical and Radiologic Anatomy. 2025. doi:10.1007/s00276-025-03599-8
BibTeX
@article{Karatas2025,
author = {Karatas, Derya and Dagtekin, Ahmet and Uygur, Saygi and Barut, Irmak Tekeli and Kara, Engin and Esen, Kaan and Avci, Emel and Baskaya, Mustafa Kemal},
title = {Influence of variations of craniovertebral junction anatomy on safe C1 lateral mass and C2 pedicle screw insertion: a cadaveric and radiologic study},
journal = {Surgical and Radiologic Anatomy},
year = {2025},
doi = {10.1007/s00276-025-03599-8}
}
EUVIMED