Anthropometric measurements of the foot cannot predict the screw diameter for fifth metatarsal fractures intramedullary fixation
Surgical and Radiologic Anatomy · 2023
DOI: 10.1007/s00276-023-03267-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgical and Radiologic Anatomy, 2023. Verfasst von Panagiotis D Symeonidis und 5 weiteren Autor:innen. Beteiligte Einrichtung: St Luke's Hospital, Panorama, Thessaloniki, Greece. Hauptthemen laut MEDLINE: Metatarsal Bones, Fractures, Bone, Foot Injuries, Ankle Injuries. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Aristotle University of Thessaloniki.
Abstract (Originalsprache)
Purpose
The present study aimed to evaluate the accuracy of anthropometric foot measurements in predicting the diameter of the intramedullary screw for fifth metatarsal fracture fixation. Secondary aim was to identify whether the fifth metatarsal intramedullary canal diameter is correlated to the fifth metatarsal length and the foot dimensions.
Methods
In 29 cadaveric feet, the maximum length of the plantar surface of the foot (PL) and the perimeter of the foot at the level of the fifth metatarsal base (PBFM) were measured using a measuring tape. Subsequently, the fifth metatarsal was excised. Using Computed Tomography scan, the metatarsal length (FML), and the horizontal (HDI) and vertical diameter (VDI) at the isthmus level were measured. The HDI values were grouped in 5 mm increments to correspond to the recommended screw diameter (RSD) for intramedullary fixation. A univariate linear regression analysis considered RSD and HDI as the dependent variables and FML, PL, PBFM as the independent variables. A multivariate regression analysis was performed to examine the predictive value of the two anthropometric measurements. A p -value < 0.05 was considered statistically significant.
Results
All six univariate analyses revealed that the dependent variable was significantly correlated with the independent variable. However, the multivariate regression models showed that the anthropometric measurements were not significantly correlated with the RSD and HDI.
Conclusion
The current study found an association between the fifth metatarsal intramedullary canal diameter and the fifth metatarsal length and foot anthropometric dimensions. However, the anthropometric measurements of the foot presented a low predictive value for the decision of an intramedullary screw diameter in the treatment of fractures of the base of the fifth metatarsal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- St Luke's Hospital, Panorama, Thessaloniki, Greece.
- Department of Anatomy and Surgical Anatomy, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece. totlis@auth.gr.
- Thessaloniki Minimally Invasive Surgery (TheMIS) Orthopaedic Center, St Luke's Hospital, Thessaloniki, Greece. totlis@auth.gr.
- School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
- Affidea Group, Budapest, Hungary.
- Department of Orthopaedic Surgery, University of Ioannina, 45110, Ioannina, Greece.
Förderung
- Aristotle University of Thessaloniki
Zitieren
APA
Symeonidis, P. D., Totlis, T., Dermitzakis, I., Papachristodoulou, A., Giatas, I., & Beris, A. (2023). Anthropometric measurements of the foot cannot predict the screw diameter for fifth metatarsal fractures intramedullary fixation. Surgical and Radiologic Anatomy. https://doi.org/10.1007/s00276-023-03267-9
Vancouver
Symeonidis PD, Totlis T, Dermitzakis I, Papachristodoulou A, Giatas I, Beris A. Anthropometric measurements of the foot cannot predict the screw diameter for fifth metatarsal fractures intramedullary fixation. Surgical and Radiologic Anatomy. 2023. doi:10.1007/s00276-023-03267-9
BibTeX
@article{Symeonidis2023,
author = {Symeonidis, Panagiotis D and Totlis, Trifon and Dermitzakis, Iasonas and Papachristodoulou, Athanasia and Giatas, Ioannis and Beris, Alexandros},
title = {Anthropometric measurements of the foot cannot predict the screw diameter for fifth metatarsal fractures intramedullary fixation},
journal = {Surgical and Radiologic Anatomy},
year = {2023},
doi = {10.1007/s00276-023-03267-9}
}
EUVIMED