Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models

Denis Gholami Bajestani, C Martin Reich, Jan Birkigt, Christina Mulik, Johannes Kauffold, Haukur Lindberg Sigmarsson, Thies Jochimsen, Bernhard Sattler, Osama Sabri, Michael Steinmetz, Andreas Melzer

CardioVascular and Interventional Radiology · 17.10.2026

DOI: 10.1007/s00270-026-04642-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, online erschienen am 17.10.2026. Verfasst von Denis Gholami Bajestani und 10 weiteren Autor:innen. Beteiligte Einrichtung: Innovation Center Computer Assisted Surgery, Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany. denis.gholami@medizin.uni-leipzig.de. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Bildung und Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluated the technical and procedural feasibility of MRI-guided stent implantation for CoA using a structured multistage preclinical evaluation protocol. Materials and methods A commercially available MR Conditional guidewire and dedicated research prototypes comprising nitinol stents, delivery systems, and balloon catheters were assessed in a three-stage protocol. Device visibility was evaluated in a standardized water phantom at 1.5 T and 3.0 T. In a polymer-based CoA vessel phantom, 10 stent implantations were performed by novices ( n = 6) and experts ( n = 4), with four separate expert-led balloon dilatations. MRI-guided stent implantation was subsequently performed in five porcine models.

Results

All devices were visible at both field strengths, with lateral artifact widths of 5.3–7.8 mm for the guidewire, 20.9–38.5 mm for the stent delivery system, 13.1–19.9 mm for the expanded stents, and 17.4–30.5 mm for the balloon catheter. Phantom stenting duration was 10.2 ± 7.2 mins for novices and 6.2 ± 2.7 mins for experts. MRI-guided stent implantation was successfully performed in all five animals, with a mean duration of 13.6 ± 7.5 mins. In one animal, balloon post-dilatation was additionally performed as a procedural proof of concept.

Conclusion

MRI-guided stent implantation for CoA is feasible within a structured multistage preclinical evaluation protocol and supports further clinical translation of radiation-free endovascular treatment.

Schlagwörter

Stichwörter der Autor:innen

Balloon angioplastyCoarctation of the aortaEndovascular treatmentMRI-guided interventionPorcine modelStent implantation

Autor:innen und Institutionen

  • Innovation Center Computer Assisted Surgery, Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany. denis.gholami@medizin.uni-leipzig.de.
  • Innovation Center Computer Assisted Surgery, Faculty of Medicine, Leipzig University, 04103, Leipzig, Germany.
  • Clinic for Ruminants and Swine, Faculty of Veterinary Medicine, Leipzig University, 04103, Leipzig, Germany.
  • Department of Nuclear Medicine, Leipzig University Hospital, 04103, Leipzig, Germany.
  • Department of Pediatric Cardiology and Intensive Care Medicine, University Medical Center, Georg-August-University, 37075, Göttingen, Germany.
  • German Center for Cardiovascular Research (DZHK), Partner Site Göttingen, 37075, Göttingen, Germany.

Förderung

  • Bundesministerium für Bildung und Forschung

Zitieren

APA

Gholami Bajestani, D., Reich, C. M., Birkigt, J., Mulik, C., Kauffold, J., Sigmarsson, H. L., Jochimsen, T., Sattler, B., Sabri, O., Steinmetz, M., & Melzer, A. (2026). Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-026-04642-w

Vancouver

Gholami Bajestani D, Reich CM, Birkigt J, Mulik C, Kauffold J, Sigmarsson HL, et al. Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models. CardioVascular and Interventional Radiology. 2026. doi:10.1007/s00270-026-04642-w

BibTeX
@article{GholamiBajestani2026,
  author = {Gholami Bajestani, Denis and Reich, C Martin and Birkigt, Jan and Mulik, Christina and Kauffold, Johannes and Sigmarsson, Haukur Lindberg and Jochimsen, Thies and Sattler, Bernhard and Sabri, Osama and Steinmetz, Michael and Melzer, Andreas},
  title = {Multistage Preclinical Evaluation of MRI-Guided Stenting for Coarctation of the Aorta using in vitro and Porcine Models},
  journal = {CardioVascular and Interventional Radiology},
  year = {2026},
  doi = {10.1007/s00270-026-04642-w}
}
Kostenlos starten →