Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2026. Verfasst von Roberto Luigi Cazzato und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France. roberto-luigi.cazzato@ch…. Hauptthemen laut MEDLINE: Bone Neoplasms, Clinical Decision-Making, Catheter Ablation, Precision Medicine. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To describe the clinical decision-making underlying the selection of the percutaneous ablation modality for bone tumors. MATERIALS AND METHODS: Two experienced interventional radiologists designed in consensus a model for ablation modality selection. Consecutive patients with primary and metastatic bone tumors were retrospectively identified. Demographic, clinical, and imaging data were collected for each tumor. The dataset was randomly divided into a training set (618/926 tumors; 66.7%) and a test set (308/926 tumors; 33.3%). A decision-tree model derived from the training set and the model proposed by the experts were both verified on the test set. Models' performance was assessed. RESULTS: The decision-tree and the experts-based models achieved comparable accuracy (81.8% vs. 80.5%; p = 0.493). For cryoablation, the experts-based model demonstrated significantly higher sensitivity (94.0% vs. 87.5%, p = 0.008), whereas the decision-tree model showed significantly higher specificity (79.3% vs. 69.3%, p = 0.001). For radiofrequency ablation, the decision-tree model exhibited substantially higher sensitivity (35.8% vs. 7.5%, p < 0.001), while the experts-based model had higher specificity (98.4% vs. 93.7%, p = 0.004). Performance for interstitial laser ablation was comparable between the two models, with no significant differences in sensitivity (98.8% vs. 98.9%, p = 1) and specificity (94.1% vs. 95.0%, p = 0.500). CONCLUSION: The experts-derived and the decision-tree models demonstrated comparable overall accuracy despite relying on the different decision-making. Prospective multicenter studies are required to determine which of these two approaches is more suited for implementation in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone NeoplasmsClinical Decision-MakingCatheter AblationPrecision MedicineHumansFemaleRetrospective StudiesDecision TreesMaleMiddle AgedHospitals, UniversityAgedSensitivity and SpecificityRadiofrequency AblationCryosurgeryAdult

Stichwörter der Autor:innen

Bone tumorsDecision treePercutaneous ablationTreatment selection

Autor:innen und Institutionen

  • Department of Interventional Radiology, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France. roberto-luigi.cazzato@chru-strasbourg.fr.
  • ICube Laboratory, University of Strasbourg, CNRS, INSA Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France. roberto-luigi.cazzato@chru-strasbourg.fr.
  • Department of Public Health Medicine, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67091, Strasbourg, Cedex, France.
  • Department of Interventional Radiology, University Hospital of Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France.
  • ICube Laboratory, University of Strasbourg, CNRS, INSA Strasbourg, 1, Place de l'Hôpital, 67000, Strasbourg, France.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Zitieren

APA

Cazzato, R. L., Severac, F., Steffen, D. A., Mandolini, M., Orkut, S., & Gangi, A. (2026). Personalizing Bone Tumor Ablation: Decision Models from the University Hospital of Strasbourg. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-026-04568-3

Vancouver

Cazzato RL, Severac F, Steffen DA, Mandolini M, Orkut S, Gangi A. Personalizing Bone Tumor Ablation: Decision Models from the University Hospital of Strasbourg. CardioVascular and Interventional Radiology. 2026. doi:10.1007/s00270-026-04568-3

BibTeX
@article{Cazzato2026,
  author = {Cazzato, Roberto Luigi and Severac, Francois and Steffen, Dominik A and Mandolini, Matilde and Orkut, Sinan and Gangi, Afshin},
  title = {Personalizing Bone Tumor Ablation: Decision Models from the University Hospital of Strasbourg},
  journal = {CardioVascular and Interventional Radiology},
  year = {2026},
  doi = {10.1007/s00270-026-04568-3}
}
Kostenlos starten →