Feasibility of an Augmented Reality Artificial Intelligence Tool for Real-Time Assessment of Thyroid Fine-Needle Aspiration Adequacy
CardioVascular and Interventional Radiology · 2026
DOI: 10.1007/s00270-026-04377-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2026. Verfasst von Paul M Gibbs und 8 weiteren Autor:innen. Beteiligte Einrichtung: Scripps Memorial Hospital, La Jolla, CA, USA. gibbs.paul@scrippshealth.org. Hauptthemen laut MEDLINE: Artificial Intelligence, Thyroid Gland, Augmented Reality. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the feasibility of developing an artificial intelligence application for real-time specimen adequacy assessment during ultrasound-guided fine needle aspiration of the thyroid gland using small, locally derived datasets and open-source AI tools. MATERIALS AND METHODS: 1,244 photomicrographic images of thyroid needle aspiration slides were used to develop training and testing datasets for a YOLOv5 convolutional neural network model. In silico performance was tested for standard metrics. The model was deployed in an application featuring a live, augmented reality microscopy display. Hands-on testing was performed using a set of 50 blinded patient specimens tested in duplicate (N=100) by human observers with no prior formal training in pathology. RESULTS: On an independent static image test set, the CNN achieved an AUROC of 0.954 (95% CI, 0.922-0.986) using images acquired with a dedicated microscope camera, with sensitivity 0.969, specificity 0.933, and accuracy 95.5%. Using images acquired with a smartphone camera, performance improved to an AUROC of 0.983 (95% CI, 0.965-1.000), with sensitivity 0.980, specificity 1.000, and accuracy 98.8%. In a simulated clinical workflow, human users assisted by the augmented reality AI tool demonstrated 96% concordance with the reference standard FNA adequacy assessment. CONCLUSION: An augmented reality microscopy tool based on a small-model CNN showed feasibility for performing real-time assessment of thyroid FNA specimen adequacy. Such a tool can enable telecytologic support of FNA assessment in radiologic facilities without an on-site pathologist.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Scripps Memorial Hospital, La Jolla, CA, USA. gibbs.paul@scrippshealth.org.
- V-Star Data, LLC, Hanoi, Vietnam.
- St. George's University School of Medicine, West Indies, Grenada.
- Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, UK.
- Imperial College London School of Medicine, London, UK.
- Department of Pathology, Scripps Health, La Jolla, CA, USA.
Zitieren
APA
Gibbs, P. M., Nguyen, D. X., Vargas, G. M., Gibbs, M. J., Sudheesh, P., Fitzpatrick, E. K., Tapia, O. R., Zhong, J., & Steele, J. B. (2026). Feasibility of an Augmented Reality Artificial Intelligence Tool for Real-Time Assessment of Thyroid Fine-Needle Aspiration Adequacy. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-026-04377-8
Vancouver
Gibbs PM, Nguyen DX, Vargas GM, Gibbs MJ, Sudheesh P, Fitzpatrick EK, et al. Feasibility of an Augmented Reality Artificial Intelligence Tool for Real-Time Assessment of Thyroid Fine-Needle Aspiration Adequacy. CardioVascular and Interventional Radiology. 2026. doi:10.1007/s00270-026-04377-8
BibTeX
@article{Gibbs2026,
author = {Gibbs, Paul M and Nguyen, Dat Xuan and Vargas, Gladys M and Gibbs, Michelle J and Sudheesh, Pranav and Fitzpatrick, Emma K and Tapia, Owen R and Zhong, Josh and Steele, Julie B},
title = {Feasibility of an Augmented Reality Artificial Intelligence Tool for Real-Time Assessment of Thyroid Fine-Needle Aspiration Adequacy},
journal = {CardioVascular and Interventional Radiology},
year = {2026},
doi = {10.1007/s00270-026-04377-8}
}
EUVIMED