Risk Factors for Target Vessel Re-intervention After Balloon Pulmonary Angioplasty in Inoperable Chronic Thromboembolic Pulmonary Hypertension
CardioVascular and Interventional Radiology · 25.08.2026 · 49 (11) · 2383-2392
DOI: 10.1007/s00270-026-04361-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, online erschienen am 25.08.2026. Verfasst von Zhihui Lu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Hypertension, Pulmonary, Pulmonary Embolism, Pulmonary Artery. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Innovative Research Group Project of the National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: This study aims to identify the risk factors of re-intervention on targeted vessels after balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH). MATERIALS AND METHODS: We retrospectively analyzed consecutive patients with inoperable CTEPH undergoing BPA at a single center. Targeted vessels and patients were classified according to whether re-intervention occurred. Mixed-effects logistic regression with a patient-level random intercept was used to identify predictors of re-intervention. The optimal threshold was determined by ROC analysis. Time to re-intervention was described by vessel-level Kaplan-Meier curves, and model performance was evaluated using the C-statistic, bootstrap internal validation, calibration plots, and decision-curve analysis. RESULTS: We enrolled 62 patients with inoperable CTEPH who underwent 168 BPA sessions and 412 targeted vessels. Re-intervention occurred in 98/412 vessels (23.8%) across 32/62 patients (51.6%). In mixed-effects logistic regression, percent diameter stenosis remained independently associated with re-intervention (OR = 1.38, 95% CI 1.23-1.54, p = 0.023), and pulmonary flow grade showed a strong graded association (p < 0.001). The combined model (percent diameter stenosis + pulmonary flow grade) showed good discrimination for re-intervention (AUC = 0.81, 95% CI 0.75-0.86). Kaplan-Meier curves demonstrated higher re-intervention rates in vessels with higher percent diameter stenosis and in those with pulmonary flow grade 0-1 (both log-rank p < 0.001). The combined model also had acceptable calibration and greater net benefit than percent diameter stenosis or pulmonary flow grade alone. CONCLUSIONS: Baseline pulmonary flow grade and percent diameter stenosis independently predict re-intervention after BPA. Vessels lacking high-grade flow and exhibiting greater stenosis may benefit from closer follow-up and staged dilatation strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
- Department of Respiratory and Critical Care Medicine, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
- Department of Respiratory and Critical Care Medicine, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. junwan2021@qq.com.
- Department of Interventional Diagnosis and Treatment, Beijing Anzhen Hospital, Capital Medical University, Beijing, China. maxi8238@yahoo.com.
Förderung
- Innovative Research Group Project of the National Natural Science Foundation of China
Zitieren
APA
Lu, Z., Zhang, C., Xiao, Y., Zhao, L., Lu, G., Wan, J., & Ma, X. (2026). Risk Factors for Target Vessel Re-intervention After Balloon Pulmonary Angioplasty in Inoperable Chronic Thromboembolic Pulmonary Hypertension. CardioVascular and Interventional Radiology, 49(11), 2383-2392. https://doi.org/10.1007/s00270-026-04361-2
Vancouver
Lu Z, Zhang C, Xiao Y, Zhao L, Lu G, Wan J, et al. Risk Factors for Target Vessel Re-intervention After Balloon Pulmonary Angioplasty in Inoperable Chronic Thromboembolic Pulmonary Hypertension. CardioVascular and Interventional Radiology. 2026;49(11):2383-2392. doi:10.1007/s00270-026-04361-2
BibTeX
@article{Lu2026,
author = {Lu, Zhihui and Zhang, Chen and Xiao, Yao and Zhao, Lei and Lu, Guanyu and Wan, Jun and Ma, Xiaohai},
title = {Risk Factors for Target Vessel Re-intervention After Balloon Pulmonary Angioplasty in Inoperable Chronic Thromboembolic Pulmonary Hypertension},
journal = {CardioVascular and Interventional Radiology},
year = {2026},
volume = {49},
number = {11},
pages = {2383--2392},
doi = {10.1007/s00270-026-04361-2}
}
EUVIMED