Comparison of Clinical Effectiveness of Drug-Coated Balloons versus Percutaneous Transluminal Angioplasty in Arteriovenous Fistulae Maturation Failure: A Multicenter Prospective Study
CardioVascular and Interventional Radiology · 2026
DOI: 10.1007/s00270-025-04336-9 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift CardioVascular and Interventional Radiology, 2026. Verfasst von Leonardo Harduin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Faculdade de Medicina, Departamento de Cirurgia Geral, Divisão de Cirurgia Vascular, Universidade Federal Fluminense, Niterói, Rio de Janeiro, 24220-…. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Arteriovenous Shunt, Surgical, Coated Materials, Biocompatible, Graft Occlusion, Vascular. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidade Federal Fluminense.
Abstract (Originalsprache)
Purpose
To evaluate arteriovenous fistula maturation and 12-month patency in patients undergoing oversized balloon angioplasty with high-pressure balloons alone or with high-pressure balloons plus drug-coated balloons as part of endovascular treatment for arteriovenous fistula maturation failure. Material and Methods This prospective, non-randomized study was conducted between 2022 and 2024 at four centers in Brazil. Patients with primary arteriovenous fistula failure underwent oversized balloon angioplasty with high-pressure balloons alone or with high-pressure balloons + drug-coated balloons. Vascular access primary and secondary patency rates were evaluated at 3, 6, and 12 months in 198 patients. The safety endpoint was the incidence of procedure-related complications. Exploratory analyses included the impact of demographic and clinical variables on primary patency rates.
Results
Technical success was achieved in 99% of patients (196/198). At 12 months, vascular access primary patency was 57.8% for high-pressure balloons + drug-coated balloons vs. 41.3% for high-pressure balloons alone ( p = 0.011). Twelve-month vascular access secondary patency rates were similar between groups (88.5% for high-pressure balloons + drug-coated balloons vs. 87.0% for high-pressure balloons alone, p = 0.69). Cox regression analysis identified oversized balloon angioplasty with drug-coated balloons and male sex as protective factors, reducing the 12 month risk of primary patency loss. In contrast, brachiocephalic arteriovenous fistulas and initial thrombosis were associated with an increased risk of patency loss.
Conclusion
Oversized balloon angioplasty with drug-coated balloons improved primary patency compared to high-pressure balloons alone. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculdade de Medicina, Departamento de Cirurgia Geral, Divisão de Cirurgia Vascular, Universidade Federal Fluminense, Niterói, Rio de Janeiro, 24220-002, Brasil. leonardoharduin@yahoo.com.br.
- Liv Care Centro Clínico, Niterói, Rio de Janeiro, Brazil. leonardoharduin@yahoo.com.br.
- Vascular Surgery Service, Hospital Ana Nery, Salvador, Bahia, Brazil.
- Vascular Surgery Service, Hospital Universitário Clementino Fraga Filho (HUCFF), Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, Rio de Janeiro, Brazil.
- Afya Hospital Dia, Brasília, Distrito Federal, Brazil.
- Liv Care Centro Clínico, Niterói, Rio de Janeiro, Brazil.
Förderung
- Universidade Federal Fluminense
Zitieren
APA
Harduin, L., Cortizo, L., Filippo, M. G., Barroso, T. A., Guerra, J. B., Mello, R. S., Gama, C. A. R., Ozima, B. K. I., Vieira, B. R., Reis, P. E. O., & Strogoff-de-Matos, J. P. (2026). Comparison of Clinical Effectiveness of Drug-Coated Balloons versus Percutaneous Transluminal Angioplasty in Arteriovenous Fistulae Maturation Failure: A Multicenter Prospective Study. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-025-04336-9
Vancouver
Harduin L, Cortizo L, Filippo MG, Barroso TA, Guerra JB, Mello RS, et al. Comparison of Clinical Effectiveness of Drug-Coated Balloons versus Percutaneous Transluminal Angioplasty in Arteriovenous Fistulae Maturation Failure: A Multicenter Prospective Study. CardioVascular and Interventional Radiology. 2026. doi:10.1007/s00270-025-04336-9
BibTeX
@article{Harduin2026,
author = {Harduin, Leonardo and Cortizo, Leonardo and Filippo, Márcio Gomes and Barroso, Thiago Almeida and Guerra, Julia Bandeira and Mello, Renata Silveira and Gama, Carlos Alexandre Rosa and Ozima, Brenda Kaori Ishiy and Vieira, Brunno Ribeiro and Reis, Paulo Eduardo Ocke and Strogoff-de-Matos, Jorge Paulo},
title = {Comparison of Clinical Effectiveness of Drug-Coated Balloons versus Percutaneous Transluminal Angioplasty in Arteriovenous Fistulae Maturation Failure: A Multicenter Prospective Study},
journal = {CardioVascular and Interventional Radiology},
year = {2026},
doi = {10.1007/s00270-025-04336-9}
}
EUVIMED