EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Effectiveness and Safety of Image-Guided Renal Biopsies: Insights from 5,235 Procedures in the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) Registry

R Ocker-Serger, M Opitz, L Klüner, D Rosok, M Drews, Y Thal, M Forsting, J Haubold, J Nadjiri, B M Schaarschmidt, S Zensen

CardioVascular and Interventional Radiology · 2025

DOI: 10.1007/s00270-025-04313-2 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift CardioVascular and Interventional Radiology, 2025. Verfasst von R Ocker-Serger und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany. Raya.Ocker-Serger@uk-essen.de. Hauptthemen laut MEDLINE: Image-Guided Biopsy, Kidney, Radiography, Interventional, Kidney Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Essen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluates the technical success, diagnostic yield, and complication rates of image-guided percutaneous renal biopsies based on multicenter registry data from the German Society for Interventional Radiology and Minimally Invasive Therapy. Materials and Methods This retrospective analysis included 5,235 renal biopsies at 176 centers in Germany, Austria, and Switzerland between 2018 and 2024. Technical success was defined as image-guided confirmed needle placement within the target lesion. Diagnostic yield is defined as proportion of procedures providing adequate samples for clinical diagnosis.

Results

CT was used for image guidance in 78.53% followed by ultrasound in 12.32%. Technical success was 98.38% and diagnostic yield 94.92%. Technical success was high in both inpatients (98.33%) and outpatients (99.26%; OR = 0.44, 95%CI 0.11–1,80; p = 0.241). The overall complication rate was 5.04%, with major complications in 0.74%. Complications were more frequent with pathological platelet counts and INR values, but none of these coagulation parameters remained independently associated in multivariable analysis. CT-guided biopsies showed higher complication rates than ultrasound-guided procedures, and this association remained after adjustment (adjusted OR 8.57, 95%CI 3.40–21.58; p < 0.001) . No fatal complications occurred within 24 h; however, three delayed deaths were documented among hospitalized patients.

Conclusion

Percutaneous image-guided renal biopsies are effective and safe, with low complication rates and high diagnostic yield. Ultrasound guidance remained independently associated with a lower complication risk, likely reflecting selection bias. Graphical abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image-Guided BiopsyKidneyRadiography, InterventionalKidney DiseasesHumansRetrospective StudiesFemaleMaleRegistriesMiddle AgedAgedTomography, X-Ray ComputedUltrasonography, InterventionalGermanyRadiology, InterventionalAdult

Stichwörter der Autor:innen

Biopsy, NeedleImage-guided biopsyKidney/pathologyPostoperative complicationsTreatment outcome

Autor:innen und Institutionen

  • Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany. Raya.Ocker-Serger@uk-essen.de.
  • Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
  • Department of Interventional Radiology, Klinikum Rechts Der Isar, Technical University of Munich, Munich, Germany.

Förderung

  • Universitätsklinikum Essen

Zitieren

APA

Ocker-Serger, R., Opitz, M., Klüner, L., Rosok, D., Drews, M., Thal, Y., Forsting, M., Haubold, J., Nadjiri, J., Schaarschmidt, B. M., & Zensen, S. (2025). Effectiveness and Safety of Image-Guided Renal Biopsies: Insights from 5,235 Procedures in the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) Registry. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-025-04313-2

Vancouver

Ocker-Serger R, Opitz M, Klüner L, Rosok D, Drews M, Thal Y, et al. Effectiveness and Safety of Image-Guided Renal Biopsies: Insights from 5,235 Procedures in the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) Registry. CardioVascular and Interventional Radiology. 2025. doi:10.1007/s00270-025-04313-2

BibTeX
@article{OckerSerger2025,
  author = {Ocker-Serger, R and Opitz, M and Klüner, L and Rosok, D and Drews, M and Thal, Y and Forsting, M and Haubold, J and Nadjiri, J and Schaarschmidt, B M and Zensen, S},
  title = {Effectiveness and Safety of Image-Guided Renal Biopsies: Insights from 5,235 Procedures in the German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) Registry},
  journal = {CardioVascular and Interventional Radiology},
  year = {2025},
  doi = {10.1007/s00270-025-04313-2}
}
Kostenlos starten →