Comparison of Dosimetry Models and Dose Thresholds for Predicting Pathologic Response to Yttrium-90 Radioembolization with Glass Microspheres
CardioVascular and Interventional Radiology · 20.08.2025 · 48 (11) · 1604-1613
DOI: 10.1007/s00270-025-04161-0 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift CardioVascular and Interventional Radiology, online erschienen am 20.08.2025. Verfasst von Kurt T Pianka und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of California San Diego, La Jolla, CA, USA. Hauptthemen laut MEDLINE: Yttrium Radioisotopes, Liver Neoplasms, Carcinoma, Hepatocellular, Embolization, Therapeutic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
PURPOSE: This study evaluated pathologic response to ablative transarterial radioembolization (TARE) and compared single-compartment, mean tumor dose, and voxel-based dosimetry thresholds for hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This is a retrospective, single-center study which included consecutive patients treated with glass microsphere TARE for a previously untreated HCC followed by liver transplantation between January 2015 - December 2024. A complete response (CR) was assigned if explant pathology showed complete pathologic necrosis (CPN) and if the patient had not undergone further treatments to the tumor. The standard single-compartment, dual-compartment mean tumor, and voxel-based doses were compared for patients with CR and without. RESULTS: Of the forty-three patients included, 29 had a CR. The only single-compartment dose threshold significantly associated with CR was ≥ 400 Gy, with a positive predictive value (PPV) of 77%. Mean tumor dose thresholds of ≥ 300 and ≥ 400 Gy were associated with CR (PPV 75 and 76%, respectively). The highest PPV for CR observed was for the voxel-based dose threshold of D95 ≥ 500 Gy, at 88%. Single-compartment, dual-compartment mean tumor, and D95 doses were all significantly associated with the likelihood of CR in separate multivariable logistic regression analyses. The incidence of AEs did not vary significantly based on the tested dose thresholds. CONCLUSION: Increasing the single- and dual-compartment dose thresholds beyond ≥ 400 Gy did not result in significant associations with CR nor improved PPV. In contrast, D95 ≥ 500 Gy was significantly associated with CR with the highest observed PPV. LEVEL OF EVIDENCE: Level 3, Local Non-random Sample.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Medicine, University of California San Diego, La Jolla, CA, USA.
- Department of Radiology, University of California San Diego, San Diego, CA, USA.
- Department of Surgery, University of California San Diego, La Jolla, CA, USA.
- Department of Radiology, The University of Alabama at Birmingham, Birmingham, AL, USA.
- Department of Radiology, Scripps Green Hospital, La Jolla, CA, USA.
- Department of Radiology, University of California San Diego, San Diego, CA, USA. zberman@health.ucsd.edu.
Förderung
- NIBIB NIH HHS
Zitieren
APA
Pianka, K. T., Barahman, M., Minocha, J., Redmond, J. W., Schnickel, G. T., Krishnasamy, V., Rose, S. C., Fowler, K. J., & Berman, Z. T. (2025). Comparison of Dosimetry Models and Dose Thresholds for Predicting Pathologic Response to Yttrium-90 Radioembolization with Glass Microspheres. CardioVascular and Interventional Radiology, 48(11), 1604-1613. https://doi.org/10.1007/s00270-025-04161-0
Vancouver
Pianka KT, Barahman M, Minocha J, Redmond JW, Schnickel GT, Krishnasamy V, et al. Comparison of Dosimetry Models and Dose Thresholds for Predicting Pathologic Response to Yttrium-90 Radioembolization with Glass Microspheres. CardioVascular and Interventional Radiology. 2025;48(11):1604-1613. doi:10.1007/s00270-025-04161-0
BibTeX
@article{Pianka2025,
author = {Pianka, Kurt T and Barahman, Mark and Minocha, Jeet and Redmond, Jonas W and Schnickel, Gabriel T and Krishnasamy, Venkatesh and Rose, Steven C and Fowler, Kathryn J and Berman, Zachary T},
title = {Comparison of Dosimetry Models and Dose Thresholds for Predicting Pathologic Response to Yttrium-90 Radioembolization with Glass Microspheres},
journal = {CardioVascular and Interventional Radiology},
year = {2025},
volume = {48},
number = {11},
pages = {1604--1613},
doi = {10.1007/s00270-025-04161-0}
}