EUVIMEDEUVIMED entdecken
Crossref

The Effect of Time Pressure on Motion Economy and Smoothness of Interventional Radiology Trainee Performance in Simulated Central Venous Line Placement

Oussama Metrouh, Hamza Ali, Sarah E Schroeppel DeBacker, Colin J McCarthy, Christopher MacLellan, Matthew R Palmer, Muneeb Ahmed, Jeffrey L Weinstein

CardioVascular and Interventional Radiology · 2024

DOI: 10.1007/s00270-024-03831-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2024. Verfasst von Oussama Metrouh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, USA. Hauptthemen laut MEDLINE: Clinical Competence, Phantoms, Imaging, Radiology, Interventional, Catheterization, Central Venous. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 13 Literaturangaben. Gefördert von: Controlled Risk Insurance Company of Vermont.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the effect of being under time pressure on procedural performance using hand motion analysis. MATERIALS AND METHODS: Eight radiology trainees performed central venous access on a phantom while recording video and hand motion data using an electromagnetic motion tracker. Each trainee performed the procedure six times: the first three trials without any prompts (control), while for the next three, they were asked to perform the task as fast as possible (time pressure). Validated hand motion metrics were analyzed, and two blinded and independent evaluators rated procedural performance using a previously validated task-specific global rating scale (GRS). Motion/time ratios and linear mixed-effect methods were used to control for time, and constants for both strategies were compared. RESULTS: Hand motion analysis showed that trainees completed the simulated procedure faster under time pressure (46 ± 18 s vs. 56 ± 27 s, p = 0.008) than during the control strategy. However, when controlling for time, trainees moved their hands 79 more centimeters (p = 0.04), made 15 more translational movements (p = 0.003) and 18 more rotational movements (p = 0.01) when under time pressure compared to at their own pace. CONCLUSION: Although trainees could perform the procedure faster under time pressure, there was a deterioration in hand motion economy and smoothness. This suggests that hand motion metrics offer a more comprehensive assessment of technical performance than time alone.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Clinical CompetencePhantoms, ImagingRadiology, InterventionalCatheterization, Central VenousHumansHandSimulation TrainingTime FactorsTask Performance and AnalysisVideo RecordingFemaleMale

Stichwörter der Autor:innen

Global rating scaleHand motion analysisTime pressure

Autor:innen und Institutionen

  • Department of Radiology, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, USA.
  • Department of Radiology, Beth Israel Deaconess Medical Center/Harvard Medical School, Boston, USA. jlweinst@bidmc.harvard.edu.

Förderung

  • Controlled Risk Insurance Company of Vermont

Zitieren

APA

Metrouh, O., Ali, H., DeBacker, S. E. S., McCarthy, C. J., MacLellan, C., Palmer, M. R., Ahmed, M., & Weinstein, J. L. (2024). The Effect of Time Pressure on Motion Economy and Smoothness of Interventional Radiology Trainee Performance in Simulated Central Venous Line Placement. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-024-03831-9

Vancouver

Metrouh O, Ali H, DeBacker SES, McCarthy CJ, MacLellan C, Palmer MR, et al. The Effect of Time Pressure on Motion Economy and Smoothness of Interventional Radiology Trainee Performance in Simulated Central Venous Line Placement. CardioVascular and Interventional Radiology. 2024. doi:10.1007/s00270-024-03831-9

BibTeX
@article{Metrouh2024,
  author = {Metrouh, Oussama and Ali, Hamza and DeBacker, Sarah E Schroeppel and McCarthy, Colin J and MacLellan, Christopher and Palmer, Matthew R and Ahmed, Muneeb and Weinstein, Jeffrey L},
  title = {The Effect of Time Pressure on Motion Economy and Smoothness of Interventional Radiology Trainee Performance in Simulated Central Venous Line Placement},
  journal = {CardioVascular and Interventional Radiology},
  year = {2024},
  doi = {10.1007/s00270-024-03831-9}
}