Comparison of Clinical and Radiological Outcomes Between Different (Balloon) Guide Catheter With and Without Inflated Balloon in Acute Ischemic Stroke Patients: A MaSQ-Registry Study
CardioVascular and Interventional Radiology · 2024
DOI: 10.1007/s00270-024-03718-9 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift CardioVascular and Interventional Radiology, 2024. Verfasst von R R M M Knapen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+ and School for Cardiovascular Diseases (CARIM), Maastricht Univer…. Hauptthemen laut MEDLINE: Ischemic Stroke, Registries. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Purpose
Balloon guide catheters (BGCs) are used in endovascular treatment (EVT) for ischemic stroke. Previous literature did not distinguish between BGC use with and without inflated balloon. This study aims to compare outcomes between non-BCG and BGC use with and without inflated balloon during EVT.
Methods
Patients who underwent EVT for anterior circulation ischemic stroke between September 2020 and February 2023 were analyzed. Patients were divided into three groups: non-BGC, BGC with inflated balloon, or BGC without inflated balloon. The primary outcome was the ordinal modified Rankin Scale (mRS) at 90-day follow-up. Secondary outcomes included expanded Thrombolysis In Cerebral Ischemia score (eTICI) and periprocedural complications. Regression analyses with BGC with inflated balloon as comparator were performed with adjustments. Subgroup analyses were conducted based on first-line thrombectomy technique.
Results
Out of 511 patients, 428 patients were included. Compared to BCG with inflated balloon, the mRS at 90 days did not differ in the group without inflated balloon (adjusted common [ac]OR: 1.07, 95%CI 0.67–1.73) or non-BGC (acOR: 1.42, 95%CI 0.83–2.42). Compared to patients treated with a BGC with inflated balloon, those treated with BGC without inflated balloon had lower eTICI scores (acOR: 0.59, 95%CI 0.37–0.94), and patients treated with non-BGC had lower chances of periprocedural complications (aOR: 0.41, 95%CI 0.20–0.86).
Conclusions
This study shows no clinical differences in ischemic stroke patients treated with BGC with inflated balloon compared to non-BGC and BGC without inflated balloon, despite lower periprocedural complication rates in the non-BGC group and lower eTICI scores in the BGC without inflated balloon group. Level of Evidence Level 3, non-controlled retrospective cohort study. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+ and School for Cardiovascular Diseases (CARIM), Maastricht University, Maastricht, The Netherlands. robrecht.knapen@mumc.nl.
- School for Cardiovascular Diseases Maastricht (CARIM), Maastricht University, Maastricht, The Netherlands. robrecht.knapen@mumc.nl.
- Department of Neurology, Zuyderland MC, Heerlen, Sittard-Geleen, The Netherlands.
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+ and School for Cardiovascular Diseases (CARIM), Maastricht University, Maastricht, The Netherlands.
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
- Department of Neurology, Maastricht University Medical Center+ and School for Cardiovascular Diseases (CARIM), Maastricht, The Netherlands.
Zitieren
APA
Knapen, R. R. M. M., Celen, M., Pinckaers, F. M. E., Wagemans, B. A. J. M., van Zwam, W. H., van Oostenbrugge, R. J., & van der Leij, C. (2024). Comparison of Clinical and Radiological Outcomes Between Different (Balloon) Guide Catheter With and Without Inflated Balloon in Acute Ischemic Stroke Patients: A MaSQ-Registry Study. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-024-03718-9
Vancouver
Knapen RRMM, Celen M, Pinckaers FME, Wagemans BAJM, van Zwam WH, van Oostenbrugge RJ, et al. Comparison of Clinical and Radiological Outcomes Between Different (Balloon) Guide Catheter With and Without Inflated Balloon in Acute Ischemic Stroke Patients: A MaSQ-Registry Study. CardioVascular and Interventional Radiology. 2024. doi:10.1007/s00270-024-03718-9
BibTeX
@article{Knapen2024,
author = {Knapen, R R M M and Celen, M and Pinckaers, F M E and Wagemans, B A J M and van Zwam, W H and van Oostenbrugge, R J and van der Leij, C},
title = {Comparison of Clinical and Radiological Outcomes Between Different (Balloon) Guide Catheter With and Without Inflated Balloon in Acute Ischemic Stroke Patients: A MaSQ-Registry Study},
journal = {CardioVascular and Interventional Radiology},
year = {2024},
doi = {10.1007/s00270-024-03718-9}
}
EUVIMED