Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2023. Verfasst von Satoru Morita und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University Hospital, Tokyo, Japan. i@imodey.com. Hauptthemen laut MEDLINE: Smartphone, Augmented Reality. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science London.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the accuracy of needle placement using a three-dimensional (3D) augmented reality (AR) protractor on smartphones (AR Puncture). MATERIALS AND METHODS: An AR protractor that can be rotated in three directions against the CT plane with angle guidance lines for smartphones was developed. The protractor center can be adjusted to an entry point by manually moving the smartphone with the protractor center fixed at the center of the screen (Fix-On-Screen) or by image tracking with a printed QR code placed at an entry point (QR-Tracking). Needle placement was performed by viewing a target line in the tangent direction with the Bull's eye method. The needle placement errors placed by four operators in six out-of-plane directions in a phantom using a smartphone (iPhone XR, Apple, Cupertino, CA, USA) were compared with two registration methods. RESULTS: No significant difference in the average needle placement error was observed between the Fix-On-Screen and QR-Tracking methods (5.6 ± 1.7 mm vs. 6.1 ± 2.9 mm, p = 0.475). The average procedural time of the Fix-On-Screen method was shorter than that of the QR-Tracking method (71.0 ± 23.9 s vs. 98.4 ± 59.5 s, p = 0.042). CONCLUSION: The accuracies of out-of-plane needle placements using the 3D AR protractor with the two registration methods were equally high, with short procedure times. In clinical use, the Fix-On-Screen registration method would be more convenient because no additional markers are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneAugmented RealityHumansNeedlesPhantoms, ImagingPunctures

Stichwörter der Autor:innen

Augmented realityInterventional radiologyNeedleProtractorPuncture

Autor:innen und Institutionen

  • Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University Hospital, Tokyo, Japan. i@imodey.com.
  • Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University Hospital, Tokyo, Japan.

Förderung

  • Japan Society for the Promotion of Science London

Zitieren

APA

Morita, S., Suzuki, K., Yamamoto, T., Endo, S., Yamazaki, H., & Sakai, S. (2023). Out-of-Plane Needle Placements Using 3D Augmented Reality Protractor on Smartphone: An Experimental Phantom Study. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-023-03357-6

Vancouver

Morita S, Suzuki K, Yamamoto T, Endo S, Yamazaki H, Sakai S. Out-of-Plane Needle Placements Using 3D Augmented Reality Protractor on Smartphone: An Experimental Phantom Study. CardioVascular and Interventional Radiology. 2023. doi:10.1007/s00270-023-03357-6

BibTeX
@article{Morita2023,
  author = {Morita, Satoru and Suzuki, Kazufumi and Yamamoto, Takahiro and Endo, Sota and Yamazaki, Hiroshi and Sakai, Shuji},
  title = {Out-of-Plane Needle Placements Using 3D Augmented Reality Protractor on Smartphone: An Experimental Phantom Study},
  journal = {CardioVascular and Interventional Radiology},
  year = {2023},
  doi = {10.1007/s00270-023-03357-6}
}
Kostenlos starten →