EUVIMEDEUVIMED entdecken
Crossref

Fully Robotic Side‐to‐Side Linear‐Stapled Anastomosis During Robotic Ivor Lewis Esophagectomy

Francesco Guerra iD, Angela Tribuzi, Giuseppe Giuliani iD, Michele Di Marino, Andrea Coratti

World Journal of Surgery · 2023

DOI: 10.1007/s00268-023-07050-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Surgery, 2023. Verfasst von Francesco Guerra und 4 weiteren Autor:innen. Beteiligte Einrichtung: AUSL Toscana Sud Est, Grosseto, Italy. fra.guerra.mail@gmail.com. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Esophageal Neoplasms. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The adoption of robotic surgery for esophageal cancer has been expanding rapidly over the recent years. In the setting of two‐field esophagectomy, different techniques exist for intrathoracic esophagogastric anastomosis, although the superiority of one over another has not been clearly demonstrated. Potential benefits in terms of anastomotic leakage and stenosis have been reported in association with a linear‐stapled anastomosis as compared to the more widespread techniques of circular mechanical and hand‐sewn reconstructions, however, there is still limited reported evidence on its application to robotic surgery. We here report our fully robotic technique of side‐to‐side, semi‐mechanical anastomosis.

Methods

All consecutive patients undergoing fully robotic esophagectomy featuring intrathoracic side‐to‐side stapled anastomosis by a single surgical team were included in this analysis. Operative technique is detailed, and perioperative data are assessed.

Results

A total of 49 patients were included. There were no intraoperative complications and no conversion occurred. The rate of overall postoperative morbidity was 25, 14% being the relative rate of major complications. With anastomotic‐related morbidity in particular, one patient developed minor anastomotic leakage.

Conclusions

Our experience demonstrates that a linear, side‐to‐side fully robotic stapled anastomosis can be created with a high technical success and minimal incidence of anastomosis‐related morbidity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresEsophageal NeoplasmsHumansEsophagectomyAnastomotic LeakTreatment OutcomeAnastomosis, SurgicalRetrospective StudiesPostoperative Complications

Autor:innen und Institutionen

  • AUSL Toscana Sud Est, Grosseto, Italy. fra.guerra.mail@gmail.com.
  • AUSL Toscana Sud Est, Grosseto, Italy.

ORCID-Profile: Francesco Guerra, Giuseppe Giuliani

Zitieren

APA

Guerra, F., Tribuzi, A., Giuliani, G., Di Marino, M., & Coratti, A. (2023). Fully Robotic Side‐to‐Side Linear‐Stapled Anastomosis During Robotic Ivor Lewis Esophagectomy. World Journal of Surgery. https://doi.org/10.1007/s00268-023-07050-0

Vancouver

Guerra F, Tribuzi A, Giuliani G, Di Marino M, Coratti A. Fully Robotic Side‐to‐Side Linear‐Stapled Anastomosis During Robotic Ivor Lewis Esophagectomy. World Journal of Surgery. 2023. doi:10.1007/s00268-023-07050-0

BibTeX
@article{Guerra2023,
  author = {Guerra, Francesco and Tribuzi, Angela and Giuliani, Giuseppe and Di Marino, Michele and Coratti, Andrea},
  title = {Fully Robotic Side‐to‐Side Linear‐Stapled Anastomosis During Robotic Ivor Lewis Esophagectomy},
  journal = {World Journal of Surgery},
  year = {2023},
  doi = {10.1007/s00268-023-07050-0}
}
Kostenlos starten →