EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Evaluation of the Efficacy and Safety of Microfocused Ultrasound Combined with 1550-nm Non-Ablative Fractional Laser for Facial Rejuvenation in Asian Patients with Fitzpatrick Skin Types III–IV: A Prospective, Randomized Split-Face, Controlled Trial

Luyue Zhang, Hongshan Liu, Xinxuan Li, Ying Chen, Mengyao Yang, Jiahua Guo, Jing Liu, Bin Chen, Weihui Zeng

Aesthetic Plastic Surgery · 2026-10 · 50 (20) · 8283-8292

DOI: 10.1007/s00266-026-06145-y ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 12.08.2026. Verfasst von Luyue Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, No. 157 Xiwu Road, Xi'an, 710004, China. Hauptthemen laut MEDLINE: Rejuvenation, Skin Aging, Ultrasonic Therapy, Lasers, Solid-State. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Xi'an Science and Technology Plan Project, Xi'an Jiaotong University Medical Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Facial aging involves deep structural changes and superficial skin texture alterations, single-energy treatments often fail to address both dermal remodeling and skin rejuvenation comprehensively, and combination regimens may enhance outcomes by targeting complementary layers. This study aimed to evaluate the efficacy and safety of microfocused ultrasound (MFU) combined with 1550-nm non-ablative fractional laser (NAFL) in facial rejuvenation for Asian patients with Fitzpatrick skin types III-IV. OBJECTIVES: To assess the efficacy and safety of MFU combined with 1550-nm NAFL in improving facial laxity, wrinkles, and pigmentation. METHODS: A prospective, randomized, evaluator-blinded, split-face study was conducted with 22 participants (44 facial sides) with facial photoaging. MFU was applied to both sides, with one side followed by 1550-nm NAFL. Two therapy sessions with a 6-week interval were held. Evaluations were conducted at baseline, 6, 12, and 24 weeks, using biometric and ultrasound measurements to assess treatment efficacy. Safety was assessed based on adverse events (AEs). RESULTS: All enrolled participants presented with Fitzpatrick skin types III-IV, and 22 participants completed the 24-week follow-up. Compared to baseline, both sides showed significant improvements in IASLSS, FWS, PIS, dermal thickness, skin relaxation time, MI, and EI (all P 0.05). CONCLUSIONS: MFU combined with 1550-nm NAFL is effective and safe for facial rejuvenation. The combined therapy provides superior improvement in facial wrinkles, pigmentation, and patient satisfaction rates. LEVEL OF EVIDENCE I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RejuvenationSkin AgingUltrasonic TherapyLasers, Solid-StateLaser TherapyLow-Level Light TherapyHumansFemaleProspective StudiesMiddle AgedAdultTreatment OutcomeMaleAsian PeopleCombined Modality TherapySingle-Blind MethodPatient SatisfactionFaceCosmetic TechniquesFollow-Up Studies

Stichwörter der Autor:innen

1550-nm non-ablative fractional laserFacial rejuvenationMicrofocused ultrasound

Autor:innen und Institutionen

  • Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, No. 157 Xiwu Road, Xi'an, 710004, China.
  • State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, China. chenbin@xjtu.edu.cn.
  • Department of Dermatology, The Second Affiliated Hospital of Xi'an Jiaotong University, No. 157 Xiwu Road, Xi'an, 710004, China. zengwh88@126.com.

Förderung

  • National Natural Science Foundation of China
  • Xi'an Science and Technology Plan Project
  • Xi'an Jiaotong University Medical Development Fund

Zitieren

APA

Zhang, L., Liu, H., Li, X., Chen, Y., Yang, M., Guo, J., Liu, J., Chen, B., & Zeng, W. (2026). Evaluation of the Efficacy and Safety of Microfocused Ultrasound Combined with 1550-nm Non-Ablative Fractional Laser for Facial Rejuvenation in Asian Patients with Fitzpatrick Skin Types III–IV: A Prospective, Randomized Split-Face, Controlled Trial. Aesthetic Plastic Surgery, 50(20), 8283-8292. https://doi.org/10.1007/s00266-026-06145-y

Vancouver

Zhang L, Liu H, Li X, Chen Y, Yang M, Guo J, et al. Evaluation of the Efficacy and Safety of Microfocused Ultrasound Combined with 1550-nm Non-Ablative Fractional Laser for Facial Rejuvenation in Asian Patients with Fitzpatrick Skin Types III–IV: A Prospective, Randomized Split-Face, Controlled Trial. Aesthetic Plastic Surgery. 2026;50(20):8283-8292. doi:10.1007/s00266-026-06145-y

BibTeX
@article{Zhang2026,
  author = {Zhang, Luyue and Liu, Hongshan and Li, Xinxuan and Chen, Ying and Yang, Mengyao and Guo, Jiahua and Liu, Jing and Chen, Bin and Zeng, Weihui},
  title = {Evaluation of the Efficacy and Safety of Microfocused Ultrasound Combined with 1550-nm Non-Ablative Fractional Laser for Facial Rejuvenation in Asian Patients with Fitzpatrick Skin Types III–IV: A Prospective, Randomized Split-Face, Controlled Trial},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {20},
  pages = {8283--8292},
  doi = {10.1007/s00266-026-06145-y}
}
Kostenlos starten →