EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Autologous Plasma Gel as a Dermal Filler: A Head-to-Head Experimental Comparison with Hyaluronic Acid Fillers and Fat Grafts in a Rat Model

Oguz Atan, Murat Celik, Nezih Sungur, Kadri Ozer, Hakan Teymur, Gokay Baykara, Muzaffer Caydere, Sema Hucumenoglu, Pinar Nercis Kosar, Ugur Kocer

Aesthetic Plastic Surgery · 2026-08 · 50 (15) · 6432-6445

DOI: 10.1007/s00266-026-06041-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 30.06.2026. Verfasst von Oguz Atan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic, Reconstructive and Aesthetic Surgery, Ankara Training and Research Hospital, Ankara, Turkey. Hauptthemen laut MEDLINE: Hyaluronic Acid, Dermal Fillers, Adipose Tissue, Plasma. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sivas Cumhuriyet University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Dermal fillers are widely used in aesthetic practice; however, none fully meet expectations in terms of biocompatibility, predictability, and long-term stability. Autologous plasma gel (PG) has been proposed as a biological alternative, yet comparative experimental data remain limited.

Objective

To evaluate PG as a dermal filler and compare its volumetric behavior and histopathological characteristics with hyaluronic acid fillers and autologous fat graft (FG) in a rat model.

Methods

Thirty-two male Sprague–Dawley rats were included. In a within-subject design, PG, FG, and two commercial hyaluronic acid fillers (HA-1 and HA-2) were injected into predefined dorsal quadrants. Volumetric assessment was performed using computed tomography at 1, 3, and 5 months. Histopathological evaluation focused on material persistence, neovascularization, and inflammatory response.

Results

At 1–3 months, PG demonstrated lower volume compared with the other materials. By 5 months, no significant differences were observed. Despite lower early volume, PG exhibited a more stable volumetric profile over time compared with FG and became comparable to hyaluronic acid fillers at later time points. Histologically, PG showed lower inflammatory and neovascularization scores, while material persistence remained similar across groups.

Conclusions

PG demonstrated favorable biocompatibility and a stable longitudinal volume profile in this experimental model. Although early volume was lower, long-term outcomes were comparable to established fillers, supporting further clinical investigation of PG as an autologous filler option. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hyaluronic AcidDermal FillersAdipose TissuePlasmaAnimalsMaleRats, Sprague-DawleyRatsGelsModels, AnimalTransplantation, Autologous

Stichwörter der Autor:innen

Animal modelAutologous fillerBiocompatibilityDermal fillerFat graftingHyaluronic acidPlasma gel

Substanzen

Hyaluronic AcidDermal FillersGels

Autor:innen und Institutionen

  • Department of Plastic, Reconstructive and Aesthetic Surgery, Ankara Training and Research Hospital, Ankara, Turkey.
  • Private Practice, Ankara, Turkey.
  • Department of Plastic, Reconstructive and Aesthetic Surgery, Sivas Cumhuriyet University, 58070, Sivas, Turkey. mucetr@gmail.com.
  • Department of Plastic, Reconstructive and Aesthetic Surgery, Istanbul Florence Nightingale Hospital, Istanbul, Turkey.
  • Private Practice, Istanbul, Turkey.
  • Department of Pathology, Ankara Training and Research Hospital, Ankara, Turkey.

Förderung

  • Sivas Cumhuriyet University

Zitieren

APA

Atan, O., Celik, M., Sungur, N., Ozer, K., Teymur, H., Baykara, G., Caydere, M., Hucumenoglu, S., Kosar, P. N., & Kocer, U. (2026). Autologous Plasma Gel as a Dermal Filler: A Head-to-Head Experimental Comparison with Hyaluronic Acid Fillers and Fat Grafts in a Rat Model. Aesthetic Plastic Surgery, 50(15), 6432-6445. https://doi.org/10.1007/s00266-026-06041-5

Vancouver

Atan O, Celik M, Sungur N, Ozer K, Teymur H, Baykara G, et al. Autologous Plasma Gel as a Dermal Filler: A Head-to-Head Experimental Comparison with Hyaluronic Acid Fillers and Fat Grafts in a Rat Model. Aesthetic Plastic Surgery. 2026;50(15):6432-6445. doi:10.1007/s00266-026-06041-5

BibTeX
@article{Atan2026,
  author = {Atan, Oguz and Celik, Murat and Sungur, Nezih and Ozer, Kadri and Teymur, Hakan and Baykara, Gokay and Caydere, Muzaffer and Hucumenoglu, Sema and Kosar, Pinar Nercis and Kocer, Ugur},
  title = {Autologous Plasma Gel as a Dermal Filler: A Head-to-Head Experimental Comparison with Hyaluronic Acid Fillers and Fat Grafts in a Rat Model},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {15},
  pages = {6432--6445},
  doi = {10.1007/s00266-026-06041-5}
}
Kostenlos starten →