EUVIMEDEUVIMED entdecken
Crossref

Optimizing the Septal Donor Site in Asian Rhinoplasty: A Computed Tomography-Based Simulation of the Bony-Cartilaginous Unit and Skull Base Safety

Chuong Dinh Nguyen, Dan Nhat-Linh Chau, Huy Quang Nguyen, Tho Thi-Kieu Nguyen

Aesthetic Plastic Surgery · 2026-08 · 50 (15) · 6060-6067

DOI: 10.1007/s00266-026-06019-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aesthetic Plastic Surgery, online erschienen am 16.06.2026. Verfasst von Chuong Dinh Nguyen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Postgraduate Training, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam. Hauptthemen laut MEDLINE: Rhinoplasty, Tomography, X-Ray Computed, Nasal Septum, Asian People. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Asian rhinoplasty frequently requires robust structural support to counteract a thick skin envelope. However, relying solely on septal cartilage often leads to graft depletion after preserving a safety L-strut. This study quantifies the volumetric sufficiency of the composite bony-cartilaginous unit to address this limitation while ensuring skull base safety. METHODS: A retrospective computed tomography analysis was performed on 116 Asian adults (60 men, 56 women). A standardized harvest template was virtually executed, assuming the preservation of a 10-mm L-strut. Total septal area, harvestable cartilage, and the composite bony-cartilaginous unit (cartilage, perpendicular plate of the ethmoid, and vomer) were quantified using defined anatomical landmarks. RESULTS: The harvestable septal cartilage averaged 461.5 mm2, which was significantly smaller in women than in men (p < 0.001). Expanding the harvest to include the bony septum yielded a composite area of 992.0 mm2, representing a 2.21-fold increase in graft availability. Radiographic analysis established critical safety landmarks: the mean skull base angle was 123.6°, the distance from the anterior nasal spine to the cribriform plate was 48.9 mm, and the distance to the anterior sphenoid wall was 54.3 mm. CONCLUSIONS: Septal cartilage is an inherently scarce resource in Asian rhinoplasty, particularly in females. Harvesting the septum as a bony-cartilaginous unit safely and reliably doubles the graft supply. With precise osteotomy trajectories, this composite graft eliminates the need for distant donor site morbidity, serving as an optimal local reserve. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RhinoplastyTomography, X-Ray ComputedNasal SeptumAsian PeopleTransplant Donor SiteSkull BaseTissue and Organ HarvestingNasal CartilagesHumansFemaleMaleRetrospective StudiesAdultCohort StudiesRisk AssessmentMiddle AgedYoung AdultTreatment OutcomeCartilageTransplantation, Autologous

Stichwörter der Autor:innen

Autologous graftNasal septumPerpendicular plate of ethmoidRhinoplasty

Autor:innen und Institutionen

  • Department of Postgraduate Training, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
  • Department of Plastic and Reconstructive Surgery, Gia Dinh People's Hospital, 01 No Trang Long, Gia Dinh Ward, Ho Chi Minh City, Vietnam.
  • Department of Otolaryngology- Head and Neck Surgery, University of Medicine and Pharmacy at Ho Chi Minh City, 217 Hong Bang, Cho Lon Ward, Ho Chi Minh City, Vietnam.
  • Department of Diagnostic Imaging, Gia Dinh People's Hospital, Ho Chi Minh City, Vietnam.
  • Department of Plastic and Reconstructive Surgery, Gia Dinh People's Hospital, 01 No Trang Long, Gia Dinh Ward, Ho Chi Minh City, Vietnam. drkieutho@ump.edu.vn.
  • Department of Otolaryngology- Head and Neck Surgery, University of Medicine and Pharmacy at Ho Chi Minh City, 217 Hong Bang, Cho Lon Ward, Ho Chi Minh City, Vietnam. drkieutho@ump.edu.vn.

Zitieren

APA

Nguyen, C. D., Chau, D. N., Nguyen, H. Q., & Nguyen, T. T. (2026). Optimizing the Septal Donor Site in Asian Rhinoplasty: A Computed Tomography-Based Simulation of the Bony-Cartilaginous Unit and Skull Base Safety. Aesthetic Plastic Surgery, 50(15), 6060-6067. https://doi.org/10.1007/s00266-026-06019-3

Vancouver

Nguyen CD, Chau DN, Nguyen HQ, Nguyen TT. Optimizing the Septal Donor Site in Asian Rhinoplasty: A Computed Tomography-Based Simulation of the Bony-Cartilaginous Unit and Skull Base Safety. Aesthetic Plastic Surgery. 2026;50(15):6060-6067. doi:10.1007/s00266-026-06019-3

BibTeX
@article{Nguyen2026,
  author = {Nguyen, Chuong Dinh and Chau, Dan Nhat-Linh and Nguyen, Huy Quang and Nguyen, Tho Thi-Kieu},
  title = {Optimizing the Septal Donor Site in Asian Rhinoplasty: A Computed Tomography-Based Simulation of the Bony-Cartilaginous Unit and Skull Base Safety},
  journal = {Aesthetic Plastic Surgery},
  year = {2026},
  volume = {50},
  number = {15},
  pages = {6060--6067},
  doi = {10.1007/s00266-026-06019-3}
}
Kostenlos starten →