EUVIMEDEUVIMED entdecken
Leserbrief

Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images

Furkan Mehmet Özden iD, İsmail Sivri iD, Tuncay Çolak iD

Aesthetic Plastic Surgery · 2025

DOI: 10.1007/s00266-025-05485-5 ↗

Kurz gefasst

Leserbrief in der Zeitschrift Aesthetic Plastic Surgery, 2025. Verfasst von Furkan Mehmet Özden und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomy, Faculty of Medicine, Kocaeli University, Umuttepe Campus, 41380, İzmit, Kocaeli, Turkey. furkan.ozden@kocaeli.edu.tr. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Mandible, Tomography, X-Ray Computed, Cephalometry. Die Arbeit nennt 5 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This letter presents a novel, simple, and reproducible method for measuring the gonial angle using open-source imaging software, 3D Slicer. The main research question was whether a standardized three-dimensional (3D) approach could provide a practical and accurate alternative to traditional two-dimensional cephalometric techniques. METHODS: High resolution head computed tomography (CT) scans were imported into 3D Slicer (version 5.6.2). The mandible was reconstructed in 3D using volume rendering module. Two three-point planes were defined: one tangential to the mandibular body's lower border and one to the ramus' posterior border. Their angle was calculated using a Python script within 3D Slicer. RESULTS: The workflow enabled accurate and reproducible 3D gonial angle measurements, providing flexibility for real-time adjustment, repeated calculations, and enhanced anatomical accuracy over traditional methods. CONCLUSION: This approach offers a practical, cost-free, and standardized technique with potential applications in orthognathic surgery planning, asymmetry studies, and anthropological analysis of mandible. LEVEL OF EVIDENCE V: Opinions of expert anatomists. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMandibleTomography, X-Ray ComputedCephalometryHumansFemaleMaleReproducibility of ResultsAdultYoung Adult

Stichwörter der Autor:innen

AnthropometryCephalometryCraniofacial morphologyMaxillofacial imagingOrthognathic surgery

Autor:innen und Institutionen

  • Department of Anatomy, Faculty of Medicine, Kocaeli University, Umuttepe Campus, 41380, İzmit, Kocaeli, Turkey. furkan.ozden@kocaeli.edu.tr.
  • Department of Anatomy, Faculty of Medicine, Kocaeli University, Umuttepe Campus, 41380, İzmit, Kocaeli, Turkey.

ORCID-Profile: Furkan Mehmet Özden, İsmail Sivri, Tuncay Çolak

Zitieren

APA

Özden, F. M., Sivri, İ., & Çolak, T. (2025). Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images. Aesthetic Plastic Surgery. https://doi.org/10.1007/s00266-025-05485-5

Vancouver

Özden FM, Sivri İ, Çolak T. Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images. Aesthetic Plastic Surgery. 2025. doi:10.1007/s00266-025-05485-5

BibTeX
@article{zden2025,
  author = {Özden, Furkan Mehmet and Sivri, İsmail and Çolak, Tuncay},
  title = {Mandibular Gonial Angle Measurement with Anatomical Precision in 3D Volume Rendered CT Images},
  journal = {Aesthetic Plastic Surgery},
  year = {2025},
  doi = {10.1007/s00266-025-05485-5}
}
Kostenlos starten →