Pre- and Postoperative Visualization in Rhinoplasty: Effects of LED Light Panels in Aesthetic Photography on Image Integrity
Aesthetic Plastic Surgery · 2025
DOI: 10.1007/s00266-025-05360-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aesthetic Plastic Surgery, 2025. Verfasst von Iulianna C Taritsa und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street Suite 5A, Boston, MA, 02215, USA. Hauptthemen laut MEDLINE: Rhinoplasty, Photography, Lighting. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Lighting conditions for photographic documentation during pre- and postoperative visits are critical in capturing the outcomes of rhinoplasty for patients. Current standards may not provide direct side lighting, which can enhance visualization of uneven textures. We present a revised studio setup with dual-function background lights positioned perpendicular to the subject-camera axis to provide both back and side lighting. METHODS: Rhinoplasty pictures were taken in an academic hospital clinic office from six standard angles for pre- and postoperative photography. Two foreground LED continuous lights were placed at 45 degrees relative to the subject-camera axis. An additional two LED continuous lights were angled perpendicularly to the subject-camera axis and positioned at approximately half the distance between the subject and background. Rapid colorimetric image analysis was conducted, and Hex color values were compared to a reference photograph to evaluate colorimetric distortion [4]. Paired images were evaluated by four blinded providers to evaluate nasal structure distortion, image sharpness, image noise, and overall clinical fidelity. RESULTS: Color accuracy was maintained for the four-light and two-light conditions in the frontal view, with 97% and 94% fidelity compared to the true reference, respectively. In the right oblique view, fidelity for the four-light system was 99% as compared to 100% for the two-light system. Subjective provider ratings established the proposed lighting system as superior in terms of overall clinical fidelity to the standard two-light conditions in nearly all angles (87.5%). CONCLUSION: This study focuses on moving beyond primarily two foreground lighting which may be limited in terms of side-lighting effects and resultant impact on overall image quality in the goals of optimizing pre- and post-operative documentation. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Plastic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street Suite 5A, Boston, MA, 02215, USA.
- Division of Plastic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street Suite 5A, Boston, MA, 02215, USA. sjlin@bidmc.harvard.edu.
Zitieren
APA
Taritsa, I. C., Schuster, K. A., Foppiani, J., Alvarez, A. H., Lee, D., Merle, C., & Lin, S. J. (2025). Pre- and Postoperative Visualization in Rhinoplasty: Effects of LED Light Panels in Aesthetic Photography on Image Integrity. Aesthetic Plastic Surgery. https://doi.org/10.1007/s00266-025-05360-3
Vancouver
Taritsa IC, Schuster KA, Foppiani J, Alvarez AH, Lee D, Merle C, et al. Pre- and Postoperative Visualization in Rhinoplasty: Effects of LED Light Panels in Aesthetic Photography on Image Integrity. Aesthetic Plastic Surgery. 2025. doi:10.1007/s00266-025-05360-3
BibTeX
@article{Taritsa2025,
author = {Taritsa, Iulianna C and Schuster, Kirsten A and Foppiani, Jose and Alvarez, Angelica Hernandez and Lee, Daniela and Merle, Chamilka and Lin, Samuel J},
title = {Pre- and Postoperative Visualization in Rhinoplasty: Effects of LED Light Panels in Aesthetic Photography on Image Integrity},
journal = {Aesthetic Plastic Surgery},
year = {2025},
doi = {10.1007/s00266-025-05360-3}
}